AQZ104D Panasonic Electric Works, AQZ104D Datasheet
AQZ104D
Specifications of AQZ104D
Available stocks
Related parts for AQZ104D
AQZ104D Summary of contents
Page 1
... SSRs, does not have to be used differently depending on the load. The DC-only type is well suited for control of DC solenoids and DC motors. Package Part No. AQZ102D AQZ105D SIL4-pin AQZ107D AQZ104D Package Part No. AQZ202D AQZ205D SIL4-pin AQZ207D AQZ204D 1 Form A Voltage-sensitive (AQZ10❍D, 20❍D) 4 ...
Page 2
... All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. AQZ107D AQZ104D 300 mW 200 V 400 V 1.1 A 0.6 A 3.0 A 1.5 A 100 ms (1 shot), V 1.35 W 1.35 W 2,500 Non-condensing at low (6 V < temperatures (15 V < –40°F to +212°F AQZ107D AQZ104D 1 100 0 100 1 6 0.33 Ω 1.23 Ω Max. L 0.55 Ω ...
Page 3
... IN 80 15V<V 30V –40 – 100 Ambient temperature, °C All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 1 Form A Voltage-sensitive (AQZ10❍D, 20❍D) Symbol AQZ202D AQZ205D Typical V Fon Maximum Minimum V Foff Typical Typical I IN 0.066 Ω 0.180 Ω Typical R on 0.18 Ω ...
Page 4
... Ambient temperature, °C All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 3.-(2) On resistance vs. ambient temperature characteristics (DC type) Input voltage Continuous load current: 1.1 A (DC) (AQZ107D) 0.6 A (DC) (AQZ104D) 5.0 4.0 3.0 2.0 AQZ104D 1.0 AQZ107D –40 – Ambient temperature, ° ...
Page 5
... Off state leakage current vs. load voltage characteristics Ambient temperature: 25°C 77°F –3 10 –6 10 –9 10 AQZ104D,204D AQZ107D,207D – Load voltage, V 13.-(2) Output capacitance vs. applied voltage characteristics (AC/DC type) Frequency: 1 MHz; Ambient temperature: 25°C 2000 1800 1600 1400 ...