Specifications of CSW2450-10

Load Current
50A
Circuit
SPST-NO (1 Form A)
Output Type
AC
Voltage - Input
3 ~ 32VDC
Voltage - Load
24 ~ 280 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
3VDC To 32VDC
Operating Voltage Range
24Vrms To 280Vrms
Isolation Voltage
4000Vrms
Control Voltage Type
DC
Relay Terminals
Screw Clamp
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CSW Series
PRODUCT SELECTION
Control Voltage
3-32 VDC
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (2)
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current (4) [Arms]
Minimum Load Current [Arms]
Maximum 1 Cycle Surge Current (50/60) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (with Maximum Load)
CSW2410
10A
• Ratings from 10A to 90A @ 12-280 V AC
• 3-32 V DC input range
• Low off-state leakage current (snubberless)
• SCR output for heavy industrial loads
• EMC Compliant for reliable operation in harsh environments
• Replaces the CSD/CSE series relays
CSW2425
25A
115/120
24-280
66/60
10A
0.15
1.48
600
500
1.0
1.6
0.5
10
239/250
285/259
24-280
CSW2450
25A
0.15
1.02
600
500
1.0
1.6
0.5
25
50A
1779/1621
597/625
24-280
50A
0.15
0.63
600
500
1.0
1.6
0.5
50
CSW2475
75A
4555/4150
954/1000
24-280
75A
0.25
0.31
600
500
1.0
1.6
0.5
75
CSW2490
90A
1145/1200
6560/5976
24-280
90A
0.25
0.28
600
500
1.0
1.6
0.5
90

Related parts for CSW2450-10

CSW2450-10 Summary of contents

Page 1

... V DC input range • Low off-state leakage current (snubberless) • SCR output for heavy industrial loads • EMC Compliant for reliable operation in harsh environments • Replaces the CSD/CSE series relays 25A 50A CSW2425 CSW2450 10A 25A 24-280 24-280 600 600 1.0 1 ...

Page 2

INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Minimum Turn-Off Voltage Typical Input Current Nominal Input Impedance Maximum Turn-On Time [msec] (5) Maximum Turn-Off Time [msec] GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 ...

Page 3

MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS E116949 LR81689 10143 UG Rev. 102910 ...

Page 4

...

Page 5

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords