3RHP2450D24 Crydom Co., 3RHP2450D24 Datasheet - Page 5

RELAY CONTACTOR 3PH 50A 240VAC

3RHP2450D24

Manufacturer Part Number
3RHP2450D24
Description
RELAY CONTACTOR 3PH 50A 240VAC
Manufacturer
Crydom Co.
Series
3RHPr
Datasheets

Specifications of 3RHP2450D24

Load Current
50A
Circuit
3PST (3 Form A)
Output Type
AC
Voltage - Input
22 ~ 27VDC
Voltage - Load
208 ~ 240 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Package / Case
Module
Control Voltage Range
22VDC To 27VDC
Operating Voltage Range
208Vrms To 240Vrms
Isolation Voltage
4000Vrms
Control Voltage Type
DC
Relay Terminals
Quick Connect
Contact Form
3 - NO
Coil Voltage
22 V to 27 V
Contact Rating
50 A
Contact Termination
Screw
Mounting Style
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
RHP Series - Hybrid Solid State Contactors
Part Number Nomenclature
Derating Curves
3
45
40
35
30
25
20
55
50
45
40
35
30
25
20
Three
Phase
Device
25
25
RHP
SERIES
Other Crydom products and competitive part number cross-reference available at: www.crydom.com
35
35
3RHPXX
3RHPXX
12
45
45
Operating
Voltage VAC
50/60 Hz
12:120 V 1-phase
24: 240 V 3-phase
or 1-phase
28: 280 V 3-phase
60: 600 V 3-phase
AWG # 6
AWG # 8
AWG # 6
AWG # 8
40
50
XX
40
XX
55
55
Load Current
40: 40 Amps
50: 50 Amps
D5
65
65
/Control Voltage
Nominal Coil
D12: 12 VDC
D24: 24 VDC
G: 220 VAC
F: 120 VAC
D5: 5 VDC
E: 24 VAC
75
75
Typical Electrical Connection for 3 Phase Applications
(For output voltage options 24, 28, 60)
Optional Electrical Connections for Single Phase Applications
(For output voltage options 12, 24, 28, 60)
Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX.
The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation.
In applications switching two single phase loads (R1 and R2) where the combined load current exceeds
the contactor’s rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor
(see above drawing).
~ ~ ~
Line
Neutral
~
~
Line
Neutral
Neutral
Line
~
5L3
3L2
1L1
I L1
5L3=NC
5L3
3L2
1L1
3L2
5L3
1L1
3L2
1L1
(D5, D12, D24 input versions)
DC Input/Control Voltage
(D5, D12, D24 input versions)
(D5, D12, D24 input versions)
(D5, D12, D24 input versions)
AC Input/Control Voltage
(E, F, G input versions)
AC Input/Control Voltage
AC Input/Control Voltage
AC Input/Control Voltage
DC Input/Control Voltage
DC Input/Control Voltage
DC Input/Control Voltage
(E, F, G input versions)
(E, F, G input versions)
(E, F, G input versions)
IL2 + IL3 > Rated current
6T3
4T2
2T1
6T3=NC
NC
I L1
I L2
I L3
I L2
R1
I L3
I L1
I L3
R1
R1
I L1
Load
R2
R2

Related parts for 3RHP2450D24