H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 34

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
Settings for Twin Timer Operation
Run Mode
Function Setting Mode
Present value,
OFF set time
Present value,
ON set time
OFF time range
ON time range
Timer mode
ON/OFF start mode
Input signal width
NPN/PNP input mode
Display color
Key protect level
Parameter name
Parameter name
OFF set time
Present value
ON set time
Present value
---
---
---
---
---
---
---
---
---
---
---
---
---
Parameter
oftr
ontr
timm
totm
iflt
imod
colr
kypt
Parameter
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
Same as OFF set time above
Same as OFF set time above
Same as OFF set time above
--.--s/---.-s/----s/--min--s/---.-min/----min/
--h--min/---.-h/----h/-.---s
--.--s/---.-s/----s/--min--s/---.-min/----min/
--h--min/---.-h/----h/-.---s
up/down
toff/ton
20ms/1ms
npn/pnp
red/grn/r-g/g-r
kp-1/kp-2/kp-3/kp-4/kp-5
Setting range
Setting range
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
Same as left
Same as left
Same as left
Default value
--.--s
--.--s
up
toff
20ms
npn
red
kp-1
Default
value
s
s
s
min; s
min
min
h; min
h
h
s
Same as left
Same as left
Same as left
---
---
---
---
---
---
---
---
Unit
Unit
H5CX-A/-L
Set value
Set value
34

Related parts for H5CX-L8-N AC100-240