Specifications of H3M-H-AC100/110/120-C

Relay Type
Integrated
Function
On-Delay
Circuit
DPDT (2 Form C)
Delay Time
0.3 Sec ~ 30 Min
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 120VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3MHAC100110120C
Engineering Data
Operation
■ Timing Chart
H3M
indicator lamp
Power ON
7-2 (Power)
Time-out
indicator
1-3 (NO)
8-6 (NO)
1-4 (NC)
8-5 (NC)
Set time
Load current (A)
Rt: Resetting time
Rt
Set time
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.The minimum applicable
load is 10 mA at 5 VDC (failure level: P).
H3M-H
indicator lamp
Power ON
2-7 (Power)
Time-out
indicator
8-6 (NO)
1-3 (NO)
8-5 (NC)
1-4 (NC)
Set time
Rt: Resetting time
Rt
Set time
H3M