Specifications of PM4HA-H-24VSW

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 500 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24VAC/DC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1201
Operation mode
PM4H-A
Note: Keep 0.1s or more for power off time.
ON/OFF-delay (1)
Operation type
Differential
OFF-delay
ON-flicker
ON-delay
Keep 0.05s or more for start, stop, reset input time.
Flicker
Signal
Pulse
Pulse
Pulse
ON
OF1
FO
FL
SF
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins
should be shorted ahead of time.
• Turn the operation mode selector switch to the
If pins 2 to 6 (screw-tightening pins x and c) are shorted (the start input
is turned on) with the power supply on, the output will go on after the set
time has elapsed.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the limited time interval begins,
and the output goes on after the set time has elapsed. After the output has
gone on, it goes off when the set time has elapsed, and this process is sub-
sequently repeated.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• If using a time-limit start when the power is turned on, and a reset when
the power is turned off, pins 2 to 6 (screw-tightening pins x and c)
should be shorted ahead of time.
• Turn the operation mode selector switch to the
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and after
the set time has elapsed, it goes off. This process is subsequently repeated.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
• Turn the operation mode selector switch to the
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and after
the set time has elapsed, it goes off.
Also, when pins 2 to 6 are released (the start input goes off), the output
goes on, and after the set time has elapsed, it goes off.
If the status of pins 2 to 6 (screw-tightening pins x and c) changes dur-
ing the time-limit interval (the start input goes from on to off, or from off to
on), the time-limit interval is restarted from the point at which the change
took place.
If the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to
v) are shorted (the reset input is turned on), a reset is carried out.
Note) During time-limited operation, the time-limited operation is stopped while
the pins 2 to 5 (screw-tightening pins x to b) are being shorted (the stop
input is on). When the pins are released, time-limited operation resumes.
• Turn the operation mode selector switch to the
When pins 2 to 6 (screw-tightening pins x and c) are shorted (the start
input is turned on) with the power supply on, the output goes on, and when
pins 2 to 6 (screw-tightening pins x and c) are released (the start input
is turned off), the time limit interval begins. After the set time has elapsed,
the output goes off. If start input is entered at any point during the time limit
interval, the time limit interval is reset.
Note) During time-limited operation, the time-limited operation is stopped
while the pins 2 to 5 (screw-tightening pins x to b) are being shorted
(the stop input is on). When the pins are released, time-limited operation
resumes.
2 to 6 (screw-tightening pins x and c)
Explanation
OF1
ON
FO
FL
SF
position.
position.
position.
position.
position.
Time out (N.O. contact)
Time out (N.O. contact)
Time out (N.O. contact)
Time out (N.O. contact)
Time out (N.O. contact)
Power supply
OP. LED
POWER LED
Power supply
OP. LED
POWER LED
Power supply
OP. LED
POWER LED
Power supply
OP. LED
POWER LED
Power supply
OP. LED
POWER LED
Start
Reset
Stop
Start
Reset
Stop
Start
Reset
Stop
Start
Reset
Stop
Start
Reset
Stop
Note:
Note:
Note:
Note:
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
LED lighting or No LED lighting
LED lighting or No LED lighting
LED lighting or No LED lighting
Time chart
T
LED lighting or No LED lighting
T
T
T
OFF
OFF
T: Setting time t
OFF
OFF
T
ON
ON
LED lighting
OFF
OFF
T
T
PM4H-A/S/M
ON
ON
OFF
OFF
t
ON
OFF
t
1
t
a
a
ON
ON
ON
OFF
ON
OFF
t
OFF
1
OFF
t
OFF
ON
2
t
1
a
ON
, t
t
ON
1
t
1
OFF
LED flickering
OFF
ON
ON
2
OFF
OFF
ON
t
, t
2
ON
ON
a
ON
OFF
t
, t
OFF
t
a
t
2
ON
ON
2
OFF
T
b
ON
t
ON
OFF
OFF
<T t
b
t
b
OFF
t
ON
ON
b
OFF
OFF
t
b
1
OFF
+t
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Restart
2
OFF
OFF
=T
21

Related parts for PM4HA-H-24VSW