H5CX-AD AC24/DC12-24 Omron, H5CX-AD AC24/DC12-24 Datasheet - Page 17

RELAY TIMER DGTL SPDT 12-24VDC

H5CX-AD AC24/DC12-24

Manufacturer Part Number
H5CX-AD AC24/DC12-24
Description
RELAY TIMER DGTL SPDT 12-24VDC
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AD AC24/DC12-24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CX-AD-AC24DC12-24
H5CXADAC24DC1224
Z2371
Operating Procedures
■ Setting Procedure Guide
Settings for Timer Operation
Use the following settings for all models except the H5CX-L8@.
Refer to page 19 for the H5CX-L8@.
Note: At the time of delivery, the H5CX is set for timer operation.
Settings for Twin Timer Operation
Use the following settings for all models except the H5CX-L8@.
Refer to page 27 for the H5CX-L8@.
Note: At the time of delivery, the H5CX is set for timer operation.
When Using Basic Functions Only
When Using Other Time Ranges
(9999 h, 9999 min) and Output
Modes (A-1, A-3, b, b-1, d, and Z)
When Using Basic Functions Only
When Using Other Time Ranges
(999.9 min, 9999 min, 99 h 59 min,
999.9 h, 9999 h, 9.999 s)
• Time range (0.001 s to 999.9 h,
• Output mode (A, A-2, E, F)
• Timer mode (UP/DOWN)
• Input signal width (20 ms/1 ms)
• Time range (0.01 s to 99 min 59 s)
• ON/OFF start mode
• Timer mode (UP/DOWN)
• Input signal width (20 ms/1 ms)
All the functions can be set with the operation keys.
➡For details on the setting methods, refer to page 19.
All the functions can be set with the operation keys.
➡For details on the setting methods, refer to page 27.
except 9999 h and 9999min)
(flicker OFF start/flicker ON start)
Basic Functions
Basic Functions
The settings can be performed easily with the DIP switch.
➡For details on the setting methods, refer to page 18.
The settings can be performed easily with the DIP switch.
➡For details on the setting methods, refer to page 26.
OFF
OFF
ON
ON
1
1
2
2
When Using More Detailed Setting Items
(Output Time, NPN/PNP Input Mode,
Display Color, Key Protect Level)
When Using More Detailed Setting Items
(NPN/PNP Input Mode, Display Color, Key
Protect Level)
Setting for items other than the basic functions can be
performed with the operation keys.
➡For details on the setting methods, refer to page 19.
Setting for items other than the basic functions can be
performed with the operation keys.
➡For details on the setting methods, refer to page 27.
3
3
4
4
5
5
6
6
7
7
8
8
H5CX-A/-L
17

Related parts for H5CX-AD AC24/DC12-24