I200 Fluke Electronics, I200 Datasheet

no-image

I200

Manufacturer Part Number
I200
Description
CURRENT CLAMP AC 200A
Manufacturer
Fluke Electronics
Type
AC Clampr
Datasheets

Specifications of I200

Style
Pincer
Ac Current Range
500mA ~ 200A
Bandwidth
10kHz
Cable Length
59.055" (1500.00mm)
Max Conductor Size
0.787" (20.00mm)
Termination
Banana Plug, Double, Sheathed
Ratings
CAT III 600V
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
664755
Introducing the i200/i200s
The i200 is a single range 200A clamp-on AC Current Clamp with
current output via safety shrouded banana plugs.
The i200s is a dual range 20A and 200A clamp-on AC Current
Clamp with voltage output via a safety insulated BNC connector.
A dual banana to BNC adapter is supplied to allow the i200s to be
connected to multimeters with banana input.
Unpacking
The following items should be included in your Current Clamp box:
Check the contents of the shipping box for completeness. If
something in the box has been damaged or missing, contact your
distributor or the nearest FLUKE sales or service office immediately.
Safety Information
To ensure safe operation and service of the
current clamp, follow these instructions:
4822 872 00934
July 1998, Rev. 5, 08/05
© 1998 - 2005 Fluke Corporation.
All rights reserved.
Printed in France
All product names are trademarks of
their respective companies.
Read the operating instructions before use and follow all safety
instructions.
Use the Current Clamp only as specified in the operating
instructions, otherwise the clamp’s safety features may not
protect you.
Adhere to local and national safety codes. Individual protective
equipment must be used to prevent shock and arc blast injury
where hazardous live conductors are exposed.
Do not hold the Current Clamp anywhere beyond the tactile
barrier, see Figure 1.
Before each use, inspect the Current Clamp. Look for cracks or
missing portions of the clamp housing or output cable
insulation. Also look for loose or weakened components. Pay
particular attention to the insulation surrounding the jaws.
Check the magnetic mating surfaces of the clamp jaws; these
should be free of dust, dirt, rust and other foreign matter.
Never use the clamp on a circuit with voltages higher than 600
V CAT III.
Use extreme caution when working around bare conductors or
bus bars. Contact with the conductor could result in electric
shock.
Current Clamp
Dual Banana to BNC Adapter model PM9081 (only with i200s)
Instruction Sheet (this paper)
CAT III equipment is designed to protect against transients
in equipment in fixed equipment installations, such as
distribution panels, feeders and short branch circuits, and
lighting systems in large buildings.
Read First: Safety Information.
AC Current Clamp
i200/i200s
Instruction Sheet
®
Symbols
Specifications
SAFETY
EMC
Use caution when working with voltages above 60 V dc, 30 V ac
rms or 42 V ac peak. Such voltages pose a shock hazard.
Figure 1. Safely holding the Current Clamp
Input jaws & output floating
voltage to ground
May be used on HAZARDOUS LIVE
conductors.
Product is protected by double insulation.
Risk of Danger. Important information. See
Instruction Sheet.
Risk of Electric Shock.
Conforms to relevant European standards.
Earth ground.
Tactile barrier
Complies with American
industry standards
UL61010B-1 & UL61010B-2-
032 and European standards
EN/IEC 61010-1 2nd Edition
& EN/IEC 61010-02-032 for
600V CAT III, pollution
degree 2.
Complies with standards
EN/IEC 50081-1 &
EN/IEC 50082-2
ELECTRICAL SPECIFICATIONS
20A Range (i200s only)
200A Range
Measuring range
Maximum current
Crest factor *
Maximum non-destructive
All Electrical Specifications are valid at the following reference
conditions:
Measuring range
Maximum current
Crest factor *
Maximum non-destructive
current
Output signal
Output impedance
Basic accuracy
Additional error:
Phase shift
current
Output signal
Output impedance
Basic accuracy
Additional error:
Phase shift
48 Hz to 65 Hz
40 Hz to 48 Hz and
65 Hz to 1 kHz
1 kHz to 10 kHz
Continuous
10 min ON
/30 min OFF
48 Hz to 65 Hz
40 Hz to 48 Hz and
65 Hz to 1 kHz
1 kHz to 10 kHz
0.5A to 10A
10A to 40A
40A to 100A
100A to 240A
Ambient temperature
Relative Humidity
Frequency
Continuous external field
Load impedance
The current may not contain any DC component
No influence from adjacent currents
The conductor must be centered within the jaw aperture
100A to 240A
40A to 100A
0.5A to 10A
10A to 40A
i200
+ < 3%
+ < 12%
Unspecified
≤ 5 °
≤ 3 °
≤ 2.5 °
0.5 to 240A
240A
< 3
1 mA/A
-
≤ 3% + 0.5A
≤ 2.5% + 0.5A
≤ 2% + 0.5A
≤ 1% + 0.5A
@ Frequency ≤ 1 kHz and
0.1 to 24A
24A
< 3
200A (Frequency ≤ 1 kHz and
crest factor < 3)
100 mV/A
≤ 20 Ω @ 1 kHz
≤ 2% + 0.5A
+ < 10%
+ < 15%
Unspecified
23±3°C (73±3°F)
20 to 75%
48 to 65 Hz
< 40 A/m
i200: 0.2
i200s: >1 M
crest factor < 3
200A
240A
…15
i200s
+ < 3%
+ < 12%
Unspecified
≤ 6 °
≤ 4 °
≤ 3 °
0.5 to 240A
240A
< 3
10 mV/A
≤ 10 Ω @ 1 kHz
≤ 3.5% + 0.5A
≤ 3% + 0.5A
≤ 2.5% + 0.5A
≤ 1.5% + 0.5A
// 100 pF
All ranges
*
of a superimposed transient and the ac rms value.
GENERAL
Instrument Compatibility
The i200s is compatible with any Fluke ScopeMeter test tool, Power
Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage
measurement device that has the following features:
The i200 is compatible with any Fluke Multimeter or any other
current measurement device that has the following features:
Load on output
Load Influence
Bandwidth
Additional errors
Clamp Dimensions
Protection index
Jaw Opening
Height of open Jaws
Maximum conductor size
Weight
Cable length
Temperature
Relative Humidity
Altitude
EMC
This is the maximum permissible ratio between the peak value
Operating
Non-operating
Operating
Operating
Non-operating
BNC input connector. The Dual Banana to BNC Adapter
included in the package, can be used to connect to standard
inputs on multimeters. For the 120 series ScopeMeters, use
the BB120 Shielded Banana to BNC Adapter.
Input accuracy of 2% or better to take full advantage of the
accuracy of the Current Clamp.
Input impedance of greater than or equal to 1 MΩ, and for full
bandwidth and accuracy, a maximum input capacity of 100 pF.
A pass- band of more than four times the frequency of the
waveform to be measured.
Banana inputs.
Input accuracy of 2% or better to take full advantage of the
accuracy of the Current Clamp.
Input impedance of 0.2Ω …15Ω
A pass-band of more than four times the frequency of the
waveform to be measured.
With temperature
With position of
conductor in the
clamp aperture
With adjacent
conductors
-1.5 dB
-3dB
i200
i200s
i200
0.2...15 Ω
Current: < 1%
Phase: < 1°
40 Hz to 10 kHz
40 kHz
135 x 50 x 30 mm
(5.3 x 2 x 1.2 in)
IP40
21 mm (0.82 in)
69 mm (2.7 in)
∅ 20 mm (0.8 in) or
busbar 20 x 5 mm (0.8 x 0.2 in)
180 g (6.4 oz)
1.5 m (59 in)
2m (79 in)
-10 to +55°C (+14 to +131°F)
-40 to + 70°C (-40 to +158°F)
85%, up to +30°C (+86°F)
75%, up to +55°C (+131°F)
to 2000 m (6500 ft)
to 12000 m (40000 ft)
EN/IEC 50081-1
EN/IEC 50082-2 (3V/m,
2.74V/yd)
≤ 15 mA / A @ 50 Hz
≤ 0.5 % @ 50 Hz
≤ 0.15 % / 10 K
i200s
>1 MΩ // < 100 pF
-
-
40 Hz to 10 kHz
40 kHz

I200 Summary of contents

Page 1

... The i200s is a dual range 20A and 200A clamp-on AC Current Clamp with voltage output via a safety insulated BNC connector. A dual banana to BNC adapter is supplied to allow the i200s to be connected to multimeters with banana input. Unpacking ...

Page 2

... Connect the i200/i200s Current Clamp to the desired input on the measuring instrument. i200: See Figure 2. i200s: See Figure 3. When you are using a multimeter, use the Dual Banana to BNC Adapter (PM9081) to connect the Current Clamp to the input. 2. i200s: On the Current Clamp, select the least sensitive range (10 mV/A) ...