I800 Fluke Electronics, I800 Datasheet - Page 6

no-image

I800

Manufacturer Part Number
I800
Description
CURRENT CLAMP PROBE AC
Manufacturer
Fluke Electronics
Type
AC Clampr
Datasheet

Specifications of I800

Style
Pincer
Ac Current Range
100mA ~ 800A rms
Bandwidth
10kHz
Cable Length
62.992" (1600.00mm)
Max Conductor Size
2.126" (54.00mm)
Termination
Banana Plug, Double, Sheathed
Ratings
CAT III 600V
For Use With
614-1062 - DMM TRUE RMS 50000CNT W/BCKLGHT
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2840283
Weight
Cable Length
Overload Conditions
Duty Cycle
Safety Standards
EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600 V rms, Category III, Pollution Degree 2
Use of the clamp on uninsulated conductors is limited to 600 V
ac rms or dc and frequencies below 1 kHz.
CAT III equipment is designed to protect against the transients in
the equipment in fixed equipment installations, such as
distribution panels, feeders and short branch circuits, and the
lighting systems in large buildings.
EMC Standards
EN 61326 :1998 +A1, A2, & A3
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This
warranty does not cover fuses, disposable batteries, or damage
from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not
authorized to extend any other warranty on Fluke’s behalf. To
obtain service during the warranty period, contact your nearest
Fluke authorized service center to obtain return authorization
information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE,
ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
states or countries do not allow the exclusion or limitation of an
implied warranty or of incidental or consequential damages, this
limitation of liability may not apply to you.
11/99
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
650 g
1.6 meters
Operation above 1200 A
should be limited to
frequencies below 1 kHz
1500 A at 50 / 60 Hz for 1
hour, 33 % duty cycle
(20 min ON, 40 min OFF).
Since some