I3000S FLEX-24 Fluke Electronics, I3000S FLEX-24 Datasheet - Page 8

no-image

I3000S FLEX-24

Manufacturer Part Number
I3000S FLEX-24
Description
CLAMP CURRENT AC 24IN 3000AMP
Manufacturer
Fluke Electronics
Type
AC Clampr
Datasheets

Specifications of I3000S FLEX-24

Style
Flexible Ring
Ac Current Range
30 ~ 3000A rms
Bandwidth
50kHz
Cable Length
78.740" (2000.00mm)
Max Conductor Size
7.000" (177.80mm)
Termination
BNC
Ratings
CAT III 600V
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
2584888
Measuring Current
To measure current:
1.
To avoid electric shock or injury, the flexible current
probe is not for use on conductors with a potential
of over 600 V.
2.
3.
4.
5.
To avoid electric shock or injury:
To avoid electric shock or injury, read Safety
Instructions before operating this product
Ensure that the conductor to be tested is de-
energized
Connect the output of the electronics to the input of an
oscilloscope or other data recording device.
Wrap the flexible measuring head around the conductor
to be tested in a close coupling manner.
Energize the circuit under test.
For most accurate measurement, centre the flexible
head around the conductor.
Locate coupling away from the nearby conductors.
Do not use the flexible current probe to
measure bare conductors unless wearing
protective clothing suitable for high voltage
work.
Always use appropriate equipment for personal
protection. When installed on bare
conductors/busbars, the product must be within
a suitable enclosure.
WX Warning
XWWarning
XWWarning
Ieb0001.eps