80PK-24 Fluke Electronics, 80PK-24 Datasheet - Page 4

no-image

80PK-24

Manufacturer Part Number
80PK-24
Description
PROBE AIR TEMP SUREGRIP TYPE-K
Manufacturer
Fluke Electronics
Series
SureGrip™r
Type
K-Type Thermocoupler
Datasheets

Specifications of 80PK-24

Usage
HVAC
Tip - Type
Air, Caged
Plug Type
Sub-Mini (Thermocouple Plug)
Probe Temperature Range
-40 ~ 1500°F (-40 ~ 816°C)
Cable Length
39.370" (1000.00mm)
Cable Insulation
Poly-Vinyl Chloride (PVC)
Plug Color
Yellow
Probe Length
8.500" (215.90mm)
Probe Material
Inconel
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2098691
With no heat or cold applied to the probe, the measuring
instrument should display the ambient temperature. If the
measuring instrument does not read out properly, try the
following:
1.
2.
3.
Scale Conversions
Use the following equation to convert C to F:
Use the following equation to convert F to C:
Check for an open circuit indicator on the measuring
Verify that the temperature-measuring instrument is
designed to be used with Type K thermocouples. The
temperature-measuring instrument should have a
yellow input connector and / or be marked with a “K”.
instrument. Some temperature measuring instruments
have a built-in circuit to indicate if the connected
probe is open. (All Fluke Temperature-measuring
instruments have this feature.) Refer to the owners
manual accompanying the measuring instrument to
see if this feature is available.
Short the two input pins of the measuring instrument
with a piece of wire. If the instrument is functioning, it
should indicate the ambient temperature.
If you suspect a broken connection, use an ordinary
ohmmeter to read the continuity of the probe from pin
to pin. The ohmmeter should read 20 ohms or less if
there is continuity.
( C x 1.8) + 32 = F
( F –32) x 0.5556 = C
Figure 2. 80PK-24
bag01f.eps