3. DIE INSTALLATION
4. CRIMPING PROCEDURE
2
1. Close the tool handles until the ratchet releases,
then allow the handles to open fully.
2. Insert the dies into the tool jaws as shown in
Figure 3, and align the die retaining holes in each
die with the associated holes in the tool.
3. Thread, but do not tighten, the die retaining
screws into the holes.
4. Carefully close the tool handles, making sure
that the dies align properly.
5. Tighten the die retaining screws.
1. Refer to Figure 2, and select a cap of the
correct size for the insulation diameter of the wire
being used.
2. Identify the color code of the cap, and insert the
cap into the crimping chamber with the same color
code. Be sure that the cap is fully inserted.
3. Begin closing the tool handles until the cap is
held firmly in place. Do NOT deform the cap.
PRO-CRIMPER III Hand Tool Assembly 58573-1
Figure 3
Figure 4
5. CRIMP INSPECTION
Inspect the crimped spare wire cap. The crimp should
be near the center of the insert in the cap, and the
wire should be bottomed in the cap.
Double check that the correct cap was used for the
wire’s insulation diameter, and make sure that the
correct crimping chamber was used.
If the cap fails inspection, remove the cap by cutting
the wire, then apply a new cap to the wire by carefully
following the above procedure.
CAUTION
4. Insert the unstripped wire completely into the
cap.
NOTE
5. Close the tool handles until the ratchet releases.
6. Allow the tool handles to open FULLY and
remove the crimped cap from the crimping
chamber by turning the cap and wire 1/4 turn while
pulling lightly on the wire.
When bottoming the wire in a moisture-resistant
cap, greater insertion force must be exerted on
the wire to displace the inhibitor present in the
cap.
Damaged products may not be used. If a
damaged product is evident, it must be replaced.