2. DESCRIPTION
Each die assembly consists of a nest and an indenter
(ordered separately) which are retained in the
crimping head by retainer pins. The nest is positioned
in the yoke of the crimping head, and the indenter is
positioned in the ram of the tool.
3. DIE INSTALLATION AND REMOVAL
Refer to Figure 1 and determine the correct die
assembly, wire size, product number, and tool head to
use with the die assembly.
3.1. Die Installation
2
CAUTION
DANGER
of 6
NOTE
Indenter
1. Depress the upper release button located in the
“C”–head.
2. Slide the nest into place in “C”–head. See
Figure 2.
3. Release the button and rock the die back and
forth until the nest snaps into position.
4. Activate the power unit until the lower die
release button located in the ram is exposed.
Nest
am (Advanced)
units [with U. S. customary units in brackets].
Figures are for reference only and are not drawn
to scale.
Never operate the tool with the dies removed.
To avoid personal injury, be sure to exercise
extreme caution when using the power unit.
when installing or removing dies.
ll dimensions on this document are in metric
void depressing the footswitch or trigger control
(Figure 2)
Figure 2
Die elease Button
SOLISTRAND Flag Terminal Crimping Dies
3.2. Die Removal
Obtain the correct wire, flag terminal, and crimping
tool (with correct die assembly installed) for your
application. Strip wire insulation to the dimensions
indicated in Figure 3, taking care not to nick or cut
conductor(s), and proceed as follows:
. WIRE STRIPPING AND CRIMPING PROCEDURE
.1. Wire Stripping
.2. Crimping Procedure
DANGER
5. Depress the release button.
6. Slide the indenter into position in the ram. See
Figure 2.
7. Release the button and rock the indenter back
and forth until the die snaps into position.
8. Return ram to the down position.
1. Depress the upper release button located in the
“C”–head and slide the nest out of the head.
2. Activate the power unit until the lower die
release button (located in the ram) is exposed.
3. Depress the release button and slide the
indenter out of the ram.
1. Ensure that wire size stamped on flag terminal
corresponds to wire size being used in the
application and wire size stamped on nest and
indenter.
2. Center flag terminal wire barrel in die nest.
When crimping flag terminals, hold tongue of flag
terminals against nest as shown in Figure 4. If
terminal locator is present, slide terminal into
terminal locator and press the tongue of the flag
terminal against the slope on the nest.
3. Activate power unit so that ram advances and
holds terminal in place but DOES NOT deform wire
barrel.
4. Insert stripped wire into terminal until end of
conductor is flush with or extended slightly beyond
end of wire barrel. See Figure 3.
5. Activate power unit to complete crimp.
NOTE
6. Refer to Paragraph 5.1, Crimp Inspection, for
terminal crimp inspection procedure.
caution when operating crimping head and
holding terminals or wire near the crimping dies.
If terminal sticks in die after crimping, grasp wire
close to crimp and apply a rocking motion to
remove the die.
VOID PERSON L INJURY. Exercise extreme
(Figure 2)
08-8908
ev