MT-5 Master Appliance Co, MT-5 Datasheet - Page 2

POCKET SIZED BUTANE MICROTORCH

MT-5

Manufacturer Part Number
MT-5
Description
POCKET SIZED BUTANE MICROTORCH
Manufacturer
Master Appliance Co
Type
Butane Torchr
Datasheet

Specifications of MT-5

Temperature Range
2500°F (1371°C)
Features
Refillable Fuel Tank, Child Resistant (Compliant with CPSC Regulations)
Heat Temperature Range
2500°F
Lead Free Status / RoHS Status
Not applicable / Not applicable
Voltage
-
Power - Rated
-
Lead Free Status / RoHS Status
na, Not applicable / Not applicable

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT-58L32L36FT-10T
Manufacturer:
MT
Quantity:
20 000
FUEL ADJUSTMENT
SAFETY LOCKOUT
To ignite unit (figure 2)
• Remove safety cap.
• Slide lockout lever to off position and hold in position while slowly
• After a few attempts if no flame appears, fine tune the unit’s gas flow
To adjust fuel flow (figure 4)
• Adjust the unit fuel flow by turning the black fuel flow adjustment wheel
Hands free mode (figure 3)
• To engage hands free mode follow ignition steps above and once the
Please read and understand
all warnings and instructions.
MICROTORCH MT-5
depressing ignition button.
and retry ignition step above.
at bottom of unit. A 1/4 inch turn CW/CCW will usually be all that is
needed. Note: Extreme caution must be taken not to over adjust fuel
flow. If you are unable to make proper adjustment, please call customer
service. As the gas is consumed, the gas flow can be adjusted periodi-
cally to ensure proper flame height. It is recommended that the user set
the flame height to 1/2 inch to 1 inch. If the flame height is set outside
these limits the fuel flow / flame may become unstable and cause
premature clogging or ignition failure.
unit is ignited, position slide stem button (found on backside of unit) to
full right position. This will allow hands free operation of unit.
LEVER
FUEL VIEW
BODY
CAP
IGNITION BUTTON
WINDSHIELD
Size dim.
Unit Weight
Internal tank pressure
Continuous burn time
Specifications
MORE
GAS
FLAME ADJUSTMENT
GAS FLOW VALVE STEM
BOTTOM VIEW
75x32x21mm
45g
65 g/mm2 max
20 min. - one fill
LESS
GAS
Fig. 4
To extinguish flame / Turn off gas flow
• From Normal Use: Release pressure from ignition button. Unit will shut
• From Hands free use: Slide hands free slide stem to full left position.
CAUTION:
1. Keep out of reach of children.
2. Do not touch flame guard when hot!
3. Butane gas is extremely flammable, please handle with care.
4. Always point away from eyes and body when igniting
5. Do not store under direct sunlight or anywhere that will exceed
6. Under no circumstances should you attempt to repair a damaged torch.
7. After using, let the tool cool down before storing.
Contains flammable gas under pressure. Do not use near sparks or open
flame. Do not puncture or incinerate container.
To refuel unit. (figure 1)
• Make sure the unit is OFF and COOL to touch.
• Make sure the protective cap is on nozzle.
• Use only Master Ultratane
• Flame is invisible in direct sunlight. Use caution.
• Point away from face and body when igniting.
• Use in well ventilated areas.
• Always have a fire extinguisher/ bucket of water nearby work area.
• The tank contents are visible through the clear viewing port on the unit.
Designers and Manufacturers of Heat Tools
off immediately. (figure 2)
Unit will shut off immediately (figure 3).
or operating.
104°F/40°C.
filler valve pointing up. Place nozzle of butane canister down onto refill
valve and press butane canister down and up in short duration until fuel
tank is filled. Allow 2 -3 minutes for gas to stabilize after filling unit.
Fig. 1
®
butane to refuel unit, hold unit firmly with
2420-18th Street, Racine, WI 53403 U.S.A.
PHONE: 262-633-7791
www.masterappliance.com
E-mail: sales@masterappliance.com
OFF-LOCK
Fig. 2
FAX: 262-633-9745
Fig. 3