91293-1 Tyco Electronics, 91293-1 Datasheet - Page 4

no-image

91293-1

Manufacturer Part Number
91293-1
Description
CONN COVERS LACING TERMINATION
Manufacturer
Tyco Electronics
Series
AMPMODU®r
Datasheet

Specifications of 91293-1

Tool Type
Cover Lacing Fixture
For Use With/related Products
Amplimite® 0.050 Series Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4
Cover Lacing Fixture 91293-1
8. Position the cable clamp so that the cable
bundle is centrally located on the termination
cover. To position the clamp, loosen, but do not
remove, the socket head cap screws in the cable
clamp bracket and slide the clamp to the desired
position. Refer to Figure 7.
9. After the cable is secured, untwist the wires (if
twisted) and lace the individual wires into the wire
slots. Pull each wire into the proper slot in the
comb. Continue pulling downward on each wire
until the wire is snug in the slot. When in place, the
wire should not pop out of the slot.
NOTE
10. After all of the wires are laced, slide the lacing
fixture subassembly back under the upper tooling
assembly until it butts against the stop.
NOTE
11. Pull the arbor frame handle downward to seat
and cut the wires. The action of the wires entering
the clips on the termination covers should be felt
through the handles as a slight “snap.”
12. While maintaining pressure on the arbor frame
handle, remove the cut wire ends protruding from
the lacing fixture subassembly.
13. Lift the arbor frame handle to raise the upper
tooling assembly. Slide the lacing fixture
subassembly out, then open the cable clamp.
14. Carefully push upward on the cable, and
remove the covers from the lacing fixture
subassembly.
NOTE
i
i
i
For ease of termination, start at one end of the
covers and work toward the opposite end.
If using the bench stand, remove the lacing
fixture subassembly and place it into the slide of
the arbor frame assembly. Slide the lacing fixture
subassembly back until it butts against the stop.
If necessary, a pointed instrument can be used to
help remove the wires from the inside combs.
Take care to avoid damaging the insulation or
pulling the wires out of the clip in the termination
cover.
5. REPLACEABLE PARTS
Customer–replaceable parts are listed in Figure 8.
A complete inventory should be stocked and
controlled to prevent lost time when replacement of
parts is necessary. Parts other than those listed
should be replaced by Tyco Electronics Corporation
to ensure quality and reliability. Order replacement
parts through your representative, or call
1–800–526–5142, or send a facsimile of your
purchase order to 717–986–7605, or write to:
6. REVISION SUMMARY
Revisions to this instruction sheet include:
PART NUMBER
15. After the wires are correctly seated into the
termination covers, the covers can be seated onto
the connector. For cover seating procedure, refer
to Instruction Sheet 408–9820.
CUSTOMER SERVICE (038–035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105–3608
S Updated document to corporate requirements
S Added paragraph to Section 5
Figure 8
DESCRIPTION
408-9750
C