VPP20-2800 Triad Magnetics, VPP20-2800 Datasheet

TRANSF 10VAC 5.6A WORLD SERIES

VPP20-2800

Manufacturer Part Number
VPP20-2800
Description
TRANSF 10VAC 5.6A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP20-2800

Maximum Power
56 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
20 VAC @ 2.8A
Parallel Output Voltage @ Current
10 VAC @ 5.6A
Mounting Type
Through Hole
Power Rating
56 VA
Product
World Series Transformers
Brand/series
World Series™/VPP Series
Configuration
Bobbin
Current, Secondary
5.6/2.8 A
Dielectric Strength
4000 V (RMS)
Dimensions
3"W×1-13/16"H×2-1/2"D
Frequency
50/60 Hz
Number Of Outlets
2
Phase
1
Power, Rating
56 VA
Standards
UL, CSA, VDE
Temperature, Operating
+30 °C
Termination
Thru-Hole
Voltage, Primary
115/230 VAC
Voltage, Secondary
10/20 VAC
Weight
1.7 lbs.
Mounting Style
SMD/SMT
Height
1.812 in
Length
2.5 in
Termination Style
Solder
Width
3 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
20V
Current Rating
5.6A
Transformer Mounting
PC Board
Secondary Current Nom
5.6A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 10V
Leaded Process Compatible
Yes
Output Current
5.6A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10504
237-1091
V P P 2 0 - 2800
Electrical Specifications (@25C)
1. Maximum Power: 56.0VA
2. Secondary: Series: 20.0V CT@ 2.8A
3. Voltage Regulation: 25% TYP @ full load to no load
4. Temperature Rise: 30C TYP (45C MAX allowed)
5. Insulation Resistance: 100MΩ
Construction:
Dual bobbin construction with an insulated shroud, both made of a high
temperature material that exceeds UL flammability requirements.
Safety:
These units are designed with 4000VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
World Series Transformers are designed and manufactured to meet the following
agency approvals:
Agency File:
UL: File E53148, UL 506, General Purpose.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
VDE: File 18786-3390-0001, VDE/EN 60 950, (IEC950) information Technology
Equipment.
A. Dimensions:
B. PIN DIM. : 0.045 SQ
C. WT Lbs. : 1.70
D. Schematic Diagram:
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
1.812
H
115/230V
50/60Hz
W
3
4
6
3
1
Parallel: 10.0V @ 5.6A
2.500
D
0.600
A
12
10
0.300
9
7
B
50/60Hz
115V
CONNECTION
PARALLEL
1.900
C
ML
3
1
4
6
P
P C M
-
O W E R
50/60Hz
CONNECTION
230V
Unit: In inch
MD
SERIES
2
O U N T :
T
2.500
MW
R A N S F O R M E R
6
4
3
1
W
O R L D
S
E R I E S

Related parts for VPP20-2800

VPP20-2800 Summary of contents

Page 1

... 2800 Electrical Specifications (@25C) 1. Maximum Power: 56.0VA 2. Secondary: Series: 20.0V CT@ 2.8A Parallel: 10.0V @ 5.6A 3. Voltage Regulation: 25% TYP @ full load to no load 4. Temperature Rise: 30C TYP (45C MAX allowed) 5. Insulation Resistance: 100MΩ Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... VPP20-120* 2.5 20.0V CT @0.12A VPP20-250 5.0 20.0V CT @0.25A VPP20-500 10.0 20.0V CT @0.5A D VPP20-1000 20.0 20.0V CT @1.0A VPP20-1500 30.0 20.0V CT @1.5A VPP20-2800 56.0 20.0V CT @2.8A VPP24-100* 2.5 24.0V CT @0.1A VPP24-210 5.0 24.0V CT @0.21A VPP24-420 10.0 24.0V CT @0.42A E VPP24-830 20.0 24.0V CT @0.83A VPP24-1250 30 ...

Page 3

Hi-pot tested at 4,000 VRMS. 2. ...

Related keywords