VPS12-10300 Triad Magnetics, VPS12-10300 Datasheet

XFRMR PWR 12.6VCT 10.3A QC .250

VPS12-10300

Manufacturer Part Number
VPS12-10300
Description
XFRMR PWR 12.6VCT 10.3A QC .250
Manufacturer
Triad Magnetics
Series
Chassis Mount: World Series™r
Type
Standardr
Datasheets

Specifications of VPS12-10300

Maximum Power
130 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, Center Tap
Series Output Voltage @ Current
12.6 VAC @ 10.3A
Parallel Output Voltage @ Current
6.3 VAC @ 20.6A
Mounting Type
Chassis Mount
Power Rating
130 VA
Primary Voltage Rating
230 VAC, 115 VAC
Secondary Voltage Rating
12.6 V, 6.3 V
Mounting Style
Chassis
Dimensions
2.6875 in L x 2.8125 in W x 3.375 in H
Product
World Series Transformers
Height
3.375 in
Length
2.6875 in
Termination Style
Quick Connect
Width
2.8125 in
Brand/series
World Series™/VPS Series
Configuration
Bobbin
Current, Secondary
20.6/10.3 A
Frequency
50/60 Hz
Mounting Hole Centers
2-1/4, 2-1/2 "
Number Of Outlets
2
Phase
1
Power, Rating
130 VA
Standards
UL, CSA, VDE
Temperature, Operating
+30 °C
Termination
Quick-Connect
Voltage, Primary
115/230 VAC
Voltage, Secondary
6.3/12.6 VAC
Weight
4.1 lbs.
Current Rating
20.6A
Transformer Mounting
Chassis
Transformer Type
Power
Supply Voltage
115V
Output Voltage
12.6V
Output Current
20.6A
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Secondary Voltages
2 X 6.3V
Input Voltage
115VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1254
V P S 12 - 1 0300
Electrical Specifications (@25C)
1. Maximum Power: 130.0VA
2. Secondary: Series: 12.6V CT@ 10.3A
3. Voltage Regulation: 25% TYP @ full load to no load
4. Temperature Rise: 30C TYP (45C MAX allowed)
5. Insulation Resistance: 100MΩ
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements.
Safety:
These units are designed with 4000VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
World Series Transformers are designed and manufactured to meet the following
agency approvals:
Agency File:
UL: File E53148, UL 506, General Purpose.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
VDE: File 18786-3390-0001, VDE/EN 60 950, (IEC950) information Technology
Equipment.
A. Dimensions:
B. Mounting Hole Size: 13/64”X3/8”
C. WT Lbs. : 4.1
D. Schematic Diagram:
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
3-3/8
H
115/230V
50/60Hz
2-13/16
W
6
5
2
1
Parallel: 6.3V @ 20.6A
As of manufacturing date February 2005, all standard
2-11/16
D
A
-
12
11
8
7
1-5/8
B
50/60Hz
115V
CONNECTION
PARALLEL
3/8
C
P O W E R T R A N S F O R M E R
CHASSIS MOUNT :
QUICK-CONNECT WORLD SERIES
5
2
1
6
1/4
T
50/60Hz
CONNECTION
Unit: In inches
230V
SERIES
2-1/4
MW
2
1
6
5
2-1/2
ML
ML
6
5
2
1
T
D
MW
B
W
C
12
11
8
7
H

Related parts for VPS12-10300

VPS12-10300 Summary of contents

Page 1

... 0300 Electrical Specifications (@25C) 1. Maximum Power: 130.0VA 2. Secondary: Series: 12.6V CT@ 10.3A Parallel: 6.3V @ 20.6A 3. Voltage Regulation: 25% TYP @ full load to no load 4. Temperature Rise: 30C TYP (45C MAX allowed) 5. Insulation Resistance: 100MΩ Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... CT @ 4.3A A VPS10-8000 80 10. 8.0A VPS10-13000 130 10. 13.0A VPS10-17500 175 10. 17.5A VPS12-2000 25 12. 2.0A VPS12-3400 43 12. 3.4A B VPS12-6300 80 12. 6.3A VPS12-10300 130 12. 10.3A VPS12-14000 175 12. 14.0A VPS16-1600 25 16. 1.6A VPS16-2700 43 16. 2.7A C VPS16-5000 80 16. 5.0A VPS16-8100 130 16. 8.1A VPS16-11000 175 16. 11.0A VPS20-1250 25 20 ...

Page 3

Hi-pot tested at 4,000 VRMS. 2. ...