GRM32DR73A153KW01L Murata Electronics North America, GRM32DR73A153KW01L Datasheet - Page 3

CAP CER 15000PF 1KV 10% X7R 1210

GRM32DR73A153KW01L

Manufacturer Part Number
GRM32DR73A153KW01L
Description
CAP CER 15000PF 1KV 10% X7R 1210
Manufacturer
Murata Electronics North America
Series
GRMr

Specifications of GRM32DR73A153KW01L

Capacitance
0.015µF
Voltage - Rated
1000V (1kV)
Tolerance
±10%
Temperature Coefficient
X7R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Features
High Voltage
Applications
General Purpose
Package / Case
1210 (3225 Metric)
Size / Dimension
0.126" L x 0.098" W (3.20mm x 2.50mm)
Thickness
2.00mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ratings
-
Lead Spacing
-
Other names
490-3501-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GRM32DR73A153KW01L
Manufacturer:
MURATA
Quantity:
640 000
No.
16 Life
17
* "Room condition" Temperature: 15 to 35 C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
Medium Voltage High Capacitance for General Use Specifications and Test Methods
Continued from the preceding page.
Humidity
Loading
(Application:
DC250V,
DC630V
item)
Item
Appearance No marking defects
Capacitance
Change
D.F.
I.R.
Dielectric
Strength
Appearance No marking defects
Capacitance
Change
D.F.
I.R.
Dielectric
Strength
Within 15% (rated voltage: DC250V, DC630V)
Within 20% (rated voltage: DC1kV)
0.05 max.
CU0.01 F: More than 10M • F
CF0.01 F: More than 1,000M
In accordance with item No.4
Within 15%
0.05 max.
CU0.01 F: More than 10M • F
CF0.01 F: More than 1,000M
In accordance with item No.4
Specifications
Apply 120% of the rated voltage (150% of the rated voltage in
case of rated voltage: DC250V, 110% of the rated voltage in case
of rated voltage: DC1kV) for 1,000
operating temperature 3 C. Remove and let sit for 24 2hrs. at
room condition,* then measure.
The charge/discharge current is less than 50mA.
Apply the rated voltage at 40 2 C and relative humidity of 90 to
95% for 500
Remove and let sit for 24 2 hrs. at room condition,* then
measure.
•Pretreatment
•Pretreatment
Apply test voltage for 60 5 min. at test temperature.
Remove and let sit for 24 2 hrs. at room condition.*
Apply test voltage for 60 5 min. at test temperature.
Remove and let sit for 24 2 hrs. at room condition.*
+24
– 0
hrs.
Test Method
+48
– 0
hrs. at maximum

Related parts for GRM32DR73A153KW01L