Specifications of X24-009PKC-UA

Function
Transceiver, Modem
Modulation Or Protocol
FHSS
Frequency
2.4GHz ~ 2.4835GHz
Applications
General Purpose
Interface
USB
Sensitivity
-110dBm
Power - Output
17dBm (50mW)
Data Rate - Maximum
20 kbps
Voltage - Supply
5V
Package / Case
Module
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Features
-
XStream‐PKG‐U™ USB RF Modem – Product Manual v4.2B5 [2006.02.27] 
CC (Command Sequence Character) Command
BT (Guard Time Before) Command
CD (DO3 Configuration) Command
CN (Exit AT Command Mode) Command
CS (DO2 Configuration) Command
<Command Mode Options> BT Command is used
to set the DI pin silence time that must precede
the command sequence character (CC Command)
of the AT Command Mode Sequence.
Refer to the AT Command Mode section [p14] to
view the default AT Command Mode Sequence.
<Command Mode Options> CC Command is used
to set the ASCII character to be used between
Guard Times of the AT Command Mode Sequence
(BT+ CC + AT). The AT Command Mode
Sequence activates AT Command Mode (from Idle
Mode).
Refer to the AT Command Mode section [p14] to view the default AT Command Mode Sequence.
<Command Mode Options> CD Command is used
to redefine the behavior of the DO3/RX LED line.
<Command Mode Options> CN Command is used
to explicitly exit AT Command Mode.
<Serial Interfacing> CS Command is used to
select the behavior of the DO2 pin signal. This
output can provide RS-232 flow control, control
the TX enable signal (for RS-485 or RS-422
operations), or set the default level for the I/O
line passing function.
By default, DO2 provides RS-232
Send) flow control.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
(Clear-to-
AT Command: ATBT
Binary Command: 0x04 (4 decimal)
Parameter Range: 2 – 0xFFFF
Default Parameter Value: 0x0A (10 decimal)
Number of bytes returned: 2
Related Commands: AT (Guard Time After),
CC (Command Sequence Character)
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 – 0x7F
Default Parameter Value: 0x2B (ASCII “+” sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT
(Guard Time Before)
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 2
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range: 0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: RT (DI2 Configuration),
TO (DO2 Timeout)
Minimum Firmware Version Required: 4.27D
Parameter
Parameter
Value
Value
0
1
2
3
4
0
1
2
3
4
[x 100 milliseconds]
addressed to module sent
RS-232
Assert only when packet
RS-485 TX enable high
RS-485 TX enable low
Configuration
Configuration
Default high
Default low
(reserved)
RX LED
high
low
flow control