Specifications of X24-009PKC-UA

Function
Transceiver, Modem
Modulation Or Protocol
FHSS
Frequency
2.4GHz ~ 2.4835GHz
Applications
General Purpose
Interface
USB
Sensitivity
-110dBm
Power - Output
17dBm (50mW)
Data Rate - Maximum
20 kbps
Voltage - Supply
5V
Package / Case
Module
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Features
-
XStream‐PKG‐U™ USB RF Modem – Product Manual v4.2B5 [2006.02.27] 
SB (Stop Bits) Command
RT (DI2 Configuration) Command
SH (Serial Number High) Command
SL (Serial Number Low) Command
<Serial Interfacing> RT command is used to
dictate the behavior of the DI2/
Command must be issued to enable
control or binary programming.
SB Command is used to set/read the number of
stop bits in the data packets.
<Diagnostics> Set/Read the serial number high
word of the modem.
<Diagnostics> Set/Read the serial number low
word of the modem.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
/CMD line. RT
flow
AT Command: ATRT
Binary Command: 0x16 (22 decimal)
Parameter Range: 0 – 2
Default Parameter Value: 0
Number of bytes returned: 1
AT Command: ATSB
Binary Command: 0x36 (54 decimal)
Parameter Range: 0 – 1
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
Minimum Firmware Version Required: 4.27C
AT Command: ATSH
Binary Command: 0x26 (38 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
Minimum Firmware Version Required: 4.27C
Parameter
Parameter
Value
Value
0
1
2
0
1
Enable Binary Programming
Enable
Configuration
Configuration
1 stop bits
2 stop bits
disabled
Flow Control