MT9234ZBA-USB-CDC Multi-Tech Systems, MT9234ZBA-USB-CDC Datasheet - Page 23

no-image

MT9234ZBA-USB-CDC

Manufacturer Part Number
MT9234ZBA-USB-CDC
Description
MODEM V.92 DATA/FAX USB WORLD
Manufacturer
Multi-Tech Systems
Series
MultiModem® ZBAr

Specifications of MT9234ZBA-USB-CDC

Data Format
V.34, V.92
Interface
USB
Mounting Type
Desktop
Package / Case
5.7" L x 4.3" W x 1.0" H (145mm x 109mm x 25mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Other names
881-1061
Result Codes:
+A8T
Description:
Syntax:
<signal> Values:
<sig_en> Values:
<msg_en> Values: 0
<supp_delay> Values: 0
Reporting:
Result Codes:
+DCS
Description:
Syntax:
Values:
Reporting:
Result Codes:
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
OK if <v8o> = 1, 6 and <v8a> = 1, 5 and <v8cf> = 0 to FF and <v8b> = 0 to 2.
ERROR if <v8o> ≠ 1, 6 or <v8a> ≠ 1, 5 or <v8cf> ≠ 0 to FF or <v8b> ≠ 0 to 2.
OK if <signal> = 0–10 and <sig en> = 0, 1 and <msg en> = 0, 1 and <supp delay> =
ERROR if <signal> ≠ 0 to 10 or <sig en> ≠ 0, 1 or <msg en> ≠ 0, 1 or <supp delay> ≠
Send V.8 bis Signal and/or Message
Use this command to send a V.8 bis signal or message from the local DCE. This
command is only supported when V.80 is enabled.
AT+A8T=<signal>,<1st message>,<2nd message>,<sig en>,<msg en>,<supp delay>
0
1
2
3
4
5
6
7
8
9
10 Responding Esr
0
1
1
1
V.8 bis message
+A8T?
+A8T=?
OK if <signal> = 0 to 10 and <sig en> = 0, 1 and <msg en> = 0, 1 and <supp delay>
ERROR if <signal> ≠ 0 to 10 or <sig en> ≠ 0, 1 or <msg en> ≠ 0, 1 or <supp delay> ≠
Select V.42bis or V.44 Data Compression
Use this command to configure the available compression algorithms. The <v42bis>
parameter enables or disables the V.42 bis and the <v44> parameter enables or
disables V.44. This command works in conjunction with the %C command and the
result of either the %C command or the +DCS command replaces the current data
compression configuration.
AT+DCS=<v42bis>,<v44>
0,0
0,1
0,2
1,0
1,1
1,2
+DCS?
+DCS=?
OK if <v42bis> = 0, 1 and <v44> = 0 to 2.
ERROR if <v42bis> ≠ 0, 1 or <v44> ≠ 0 to 2.
None
Initiating Mre.
Initiating MRd.
Initiating CRe, low power
Initiating CRe, high power
Initiating CRd
Initiating Esi
Responding MRd, low power
Responding MRd, high power
Responding CRd
Enable detection of initiation signals. Default.
Enable detection or responding signals
Disable detection of messages. Default.
Enable detection of V.8 bis messages
Insert 1.5 second delay between transmitted V.8 bis signal and the subsequent
No delay inserted. Default.
= 0,1.
0,1.
0,1.
0,1.
Reports current or selected values.
Reports supported parameter values.
V.42bis and V.44 data compression are both disabled.
V.42bis is disabled; V.44 data compression is acceptable.
V.42bis is disabled; V.44 only when connected to a V.92 server.
V.42bis is acceptable; V.44 data compression is disabled.
V.42bis is acceptable; V.44 data compression is acceptable.
V.42bis is acceptable; V.44 only when connected to a V.92 server.
Reports current or selected values.
Reports allowed parameter values.
Chapter 1 – AT Commands, S-Registers, and Result Codes
23

Related parts for MT9234ZBA-USB-CDC