Specifications of MT9234ZBA-USB-CDC

Data Format
V.34, V.92
Interface
USB
Mounting Type
Desktop
Package / Case
5.7" L x 4.3" W x 1.0" H (145mm x 109mm x 25mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Other names
881-1061
#CBP
Description:
Syntax:
Values:
Default:
#CBR
Description:
Syntax:
Values:
Default:
#CBS
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
Callback Parity
Sets parity for the callback security messages.
AT#CBP<value>
0
1
2
0
Callback Security Reset
Clears the password and phone number in the y memory location.
AT#CBR<value>
0–29
None
Callback Enable/Disable
Enables or disables callback.
AT#CBS<value>
0
1
2
3
Disables callback security. Default.
Enables local and remote callback security.
Enables remote callback security only.
Disables callback security until local hang-up or reset.
No parity.
Odd parity.
Even parity.