M052ZAN Nuvoton Technology Corporation of America, M052ZAN Datasheet - Page 43

IC MCU 32BIT 8KB FLASH 33QFN

M052ZAN

Manufacturer Part Number
M052ZAN
Description
IC MCU 32BIT 8KB FLASH 33QFN
Manufacturer
Nuvoton Technology Corporation of America
Series
NuMicro M051™r
Datasheets

Specifications of M052ZAN

Core Processor
ARM Cortex-M0
Core Size
32-Bit
Speed
50MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 5.5 V
Data Converters
A/D 5x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
33-WFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M052ZAN
Manufacturer:
Micron Technology
Quantity:
800
Part Number:
M052ZAN
Manufacturer:
NUVOTON
Quantity:
20 000
Company:
Part Number:
M052ZAN
Quantity:
3 625
Brown-Out Detector Control Register (BODCR)
NuMicro M051
Partial of the BODCR control registers values are initiated by the flash configuration and write-
protected.
disable register protection. Reference the register REGWRPROT at address GCR_BA+0x100.
Register
BODCR
Bits
[31:8]
[7]
[6]
LVR_EN
31
23
15
7
Programming these protected bits needs to write “59h”, “16h”, “88h” to address 0x5000_0100 to
Offset
GCR_BA+18
Descriptions
Reserved
LVR_EN
BOD_OUT
BOD_OUT
30
22
14
6
R/W
R/W
Reserved
Low Voltage Reset Enable (write-protected bit)
The LVR function reset the chip when the input power voltage is lower than LVR circuit
setting. LVR function is enabled in default. The typical value of LVR is about 2.0V.
1= Enabled Low Voltage Reset function – After enable the bit, the LVR function will active
with 100uS delay for LVR output stable.(default).
0= Disabled Low Voltage Reset function
The status for Brown Out Detector output state
1= Brown Out Detector status output is 1, the detected voltage is lower than BOD_VL
setting. If the BOD_EN is “0”(disabled), this bit always response “0”
0= Brown Out Detector status output is 0, the detected voltage is higher than BOD_VL
setting
BOD_LPM
29
21
13
5
Series Technical Reference Manual
Description
Brown Out Detector Control Register
BOD_INTF
28
20
12
4
- 43 -
Reserved
Reserved
Reserved
BOD_RSTE
27
19
11
N
3
Publication Release Date: Sept 14, 2010
26
18
10
2
BOD_VL
25
17
9
1
Revision V1.2
Reset Value
0x0000_008X
BOD_EN
24
16
8
0

Related parts for M052ZAN