SV01A103AEA01B00 Murata, SV01A103AEA01B00 Datasheet - Page 9

Board Mount Motion & Position Sensors 10K OHM SMD

SV01A103AEA01B00

Manufacturer Part Number
SV01A103AEA01B00
Description
Board Mount Motion & Position Sensors 10K OHM SMD
Manufacturer
Murata

Specifications of SV01A103AEA01B00

Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SV01A103AEA01B00
Manufacturer:
MURATA
Quantity:
250
!Note
• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
sales representatives or product engineers before ordering.
!Note
No.
The tests and measurements should be conducted under the condition of 15 to 35 C of temperature 25 to 75% of relative humidity and 86 to 106 kpa of
atmospheric pressure unless otherwise specified. If questionable results occur that have been measured in accordance with the above mentioned conditions,
the tests and measurements should be conducted under the condition of 25 2 C of temperature, 45 to 55% of relative humidity and 86 to 106 kpa of
atmospheric pressure. When the potentiometer is tested after soldering on PCB, it should be tested after being kept in a room (15 to 35 C, 25 to 75%RH)
over 24 hours except "Resistance to soldering heat".
1
2
3
4
5
6
7
8
9
Linearity
Temperature Cycle
(Thermal Shock)
Humidity
Vibration
Shock
Humidity Load Life
High Temp.
Exposure
Low Temp.
Exposure
Rotational Life
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Item
Linearity should be specified a deviation with the below ideal straight line, between 140 degrees from the index point which is
50% of out put voltage.
The ideal straight line has 100%/300 degree as taper and pass the above index point.
Measurement is performed using the following measurement circuit, and the rotor should be rotated to clockwise direction.
The rotary position sensor should be subjected to Table 2 temperature for 5 cycles.
Then, the rotary position sensor should be kept in the dry box for 24 +8/-0 hrs.
The rotary position sensor should be stored in a chamber at temperature of +60 2 C and relative humidity of 90-95% for 250 8
hrs. After removing from the chamber, the rotary position sensor should be kept in the dry box for 24 +8/-0 hours.
The rotary position sensor should be tested under the condition of the amplitude of 1.5mm, the frequency range from 10 to 55Hz
(should be traversed in approximately one minute) and 2 hours in each of 3 mutually perpendicular directions (total 6 hours).
Then, the rotary position sensor should be kept in the dry box for 1-2 hrs.
The rotary position sensor should be tested under the condition of the peak acceleration 20G max. in half-sine wave and 5 shocks
in each of 3 mutually perpendicular directions (total 15 shocks). Then, the rotary position sensor should be kept in the dry box for
1-2 hrs.
Full rated continuous working voltage not exceeding 5Vdc should be applied intermittently between terminal #1 and terminal #3 of the
rotary position sensor, 1.5 hours on and 0.5 hours off, for 96 4 hours in total in a chamber at a temperature of +40 2 C and relative
humidity of 90-95%. After removing from the chamber, the rotary position sensor should be kept in the dry box for 24 +8/-0 hours.
The rotary position sensor should be stored in a chamber at the temperature of +85 3 C without loading for 250 8 hours. After
removing from the chamber, the rotary position sensor should be kept in the dry box for 24 +8/-0 hours.
The rotary position sensor should be stored in a chamber at the temperature of -40 3 C without loading for 168 4 hours. After
removing from the chamber, the rotary position sensor should be kept in the dry box for 24 +8/-0 hours.
The adjustment rotor should be continuously rotated within 160 of effective electrical rotational angle, at the rate of one cycle for
6 seconds for 1 Million cycles under the condition of +25 2 C of temperature without loading.
Output Voltage Ratio (%)
Temperature ( C)
Time (min.)
V (1-2)
V (1-3)
Sequence
X100
100%
50%
0%
-140
-40 3
30
1
Guarantee limit for linearity
Table 2: One cycle of temperature cycle
CCW
Rotational Angle ( )
SV01 Series Specifications and Test Methods
0
100% / 300
CW
5 max.
+25 2
2
+140
Test Methods
+85 3
DC5V (#3)
30
3
5 max.
+25 2
4
Connection Impedance: 1M ohm min.
GND (#1)
Output (#2)
R51E.pdf
7
09.3.26
1

Related parts for SV01A103AEA01B00