EE-1001 Omron, EE-1001 Datasheet - Page 63

Sensor Hardware & Accessories 4 Pin Connector For PMS

EE-1001

Manufacturer Part Number
EE-1001
Description
Sensor Hardware & Accessories 4 Pin Connector For PMS
Manufacturer
Omron
Datasheets

Specifications of EE-1001

Product
Connector
Connector Mounting
Cable
Gender
Female
Connector Type
Sensor
Terminal Type
Solder Lug
Accessory Type
Connector
Contact Material
Phosphor Bronze
Contact Termination
Solder
Rohs Compliant
Yes
For Use With
EE-SX67x, EE-SX47x, EE-SY67x, EE-SPY31x/41x, EE-SPX303/403, EE-SPW311/411 Sensor Models
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
Omron Photosensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EE-1001
Manufacturer:
OMRON
Quantity:
20 000
Dimensions mm (in)
Indication accuracy
Optional functions
Control outputs
Supply voltage
Control modes
Product type
PC software
Approvals
Features
Inputs
48 W X 96 H X 78 D
(1.89 X 3.77 X 3.07)
• For general purpose applications
• Dual digital display
• NEMA 4X water-resistant
• Heating or heating/cooling
1/8 DIN size
Platinum resistance
thermometer input: Pt100,
JPt100. Thermocouple models:
Type K1, K2, J1, T, E, L, U, N,
R, S, B; ES1A Non-contact
temperature sensor; Analog
input: 10 to 50mV.
Auto-tuning PID control or
ON/OFF control
Thermocouple and Platinum
resistance thermometer:
(±0.5% of indicated value or
±1˚C, whichever is greater) ±1
digit max. Analog input: ±0.5%
FS+1 digit max. CT input: ±5%
FS ±1 digit max.
Communications: RS-232C,
RS-485; Multiple set-point
event input board; Current
transformer.
100 to 240 VAC,
50/60 Hz; 24 VAC/VDC
Relay: SPST-NO, 250 VAC, 3
amps max. (resistive load);
Voltage output: 12 VDC (PNP),
max. load current: 40 mA
Current output: 4 to 20 mA DC
ThermoTools
UL, CSA, CE
Temperature and Process Controllers
construction
control
E5EN
96 H X 96 W X 96 D
(3.77 X 3.77 X 3.77)
• For general purpose applications
• Dual digital display
• NEMA 4X water-resistant
• Heating or heating/cooling
1/4 DIN size
Platinum resistance thermometer
input: Pt100, JPt100.
Thermocouple models: Type K1,
K2, J1, T, E, L, U, N, R, S, B;
ES1A Non-contact temperature
sensor; Analog input: 10 to
50mV.
Auto-tuning PID control or
ON/OFF control
Thermocouple and Platinum
resistance thermometer: (±0.5%
of indicated value or ±1˚C,
whichever is greater) ±1 digit
max. Analog input: ±0.5% FS+1
digit max. CT input: ±5% FS
±1 digit max.
Communications: RS-232C, RS-
485; Multiple set-point event
input board; Current transformer.
100 to 240 VAC,
50/60 Hz; 24 VAC/VDC
Relay: SPST-NO, 250 VAC, 3
amps max. (resistive load);
Voltage output: 12 VDC (PNP),
max. load current: 40 mA
Current output: 4 to 20 mA DC
ThermoTools
UL, CSA, CE
construction
control
E5AN
Controller:
72.8 H x 22.5 W (2.87 x 0.89)
With socket:
130 H x 22.5 W x 112 D
(5.12 x 0.89 x 4.41)
• For applications that need
• Can be programmed via
• Can combine 16 units for
• Socket mountable
DIN Process Controller
Thermocouples: Types K, J, T,
E, L, U, N, R, S, B; Infrared
temperature sensor: 10 to 70˚C,
60 to 120˚C, 115 to 165˚C, 160
to 260˚C (ES1A series); Voltage
input: 0 to 50 mV Platinum
resistance thermometer: Pt100,
JPt100
2-PID or ON/OFF control
Thermocouple and platinum
resistance thermometer:
(±5% of indication value or
±1%˚C, whichever is greater)
±1 digit max. Analog input:
±5%FS ±1 digit max.
CT input: ±0.5%FS
±1 digit max.
Heater burn out detection,
Multi-SP and run/stop
switching using event input
communications; Serial
communications; RS-485
24 VDC
Voltage output: 12 VSDC ±15%
(PNP); Max. load current: 21 mA,
with short-circuit protection
circuit; Transistor output: Max.
operating voltage: 30 VDC; Max.
load current: 100 mA; Residual
voltage: 1.5V max.; Leakage
current 0.4 mA max.
CX-DNC Thermo
UL, CSA, CE
multi-loop controlling
communications (RS-485) or
E5ZN-SDL display unit
32 temperature loops
E5ZN
E5AR: 96 H X 96 W X 96 D
(3.77 X 3.77 X 3.77);
E5ER: 48 W X 96 H X 78 D
(1.89 X 3.77 X 3.07)
• Up to 6 event inputs
• Up to 2 transfer outputs
• RS-485 serial communications
• Control up to 4 loops with a
DeviceNet Compatible Digital
Controller
Thermocouple: K, J, T, E, L, U, N, R,
S, B, W; Platinum resistance
thermometer: Pt100; Current input: 4
to 20 mA DC, 0 to 20 mA DC
(including remote SP input); Voltage
input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10
VDC (including remote SP input);
(Input impedance: 150 Ω for current
input, approx. 1 MΩ for voltage input)
2-PID or ON/OFF control
Thermocouple input with cold junction
compensation: (±0.1% of PV or ±1°C,
whichever is greater) ±1 digit max.;
Thermocouple input without cold
junction compensation: (±0.1% FS or
±1°C, whichever is smaller) ±1 digit;
Analog input: ±0.1% FS ±1 digit max.;
Platinum resistance thermometer
input: (±0.1% of PV or ±0.5°C,
whichever is greater) ±1 digit max.;
Position-proportional potentiometer
input: ±5% FS ±1 digit max.
Communications: RS-485,
DeviceNet; 4 event inputs board
position proportional control
100 to 240-VAC models: 50 A max.;
24 VAC/VDC models: 30 A
max.DeviceNet power supply: 24 VDC
Voltage (pulse)output: 12 VDC,
40 mA max. with short-circuit
protection circuit; Current output:
0 to 20 mA DC, 4 to 20 mA DC;
load: 500 Ω max. (including
transfer output) (Resolution:
Approx. 54,000 for 0 to 20 mA
DC; Approx. 43,000 for 4 to 20
mA DC);Relay output: Position-
proportional control type (open,
closed) N.O., 250 VAC, 1 A
(including inrush current)
ThermoTools
cRUus, CE
single unit
E5AR and E5ER
61

Related parts for EE-1001