PKU4513PI Ericsson Power Modules, PKU4513PI Datasheet - Page 29

DC/DC Converters & Regulators 12Vdc 4.2A Isolated Input 36-75V 50W

PKU4513PI

Manufacturer Part Number
PKU4513PI
Description
DC/DC Converters & Regulators 12Vdc 4.2A Isolated Input 36-75V 50W
Manufacturer
Ericsson Power Modules
Series
PKUr
Datasheet

Specifications of PKU4513PI

Output Power
50 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
4.2 A
Isolation Voltage
1.5 KV
Package / Case Size
Sixteenth Brick
Output Type
Isolated
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKU4513PI
Manufacturer:
ERICSSON
Quantity:
12 000
EMC Specification
Conducted EMI measured according to EN55022, CISPR 22
and FCC part 15J (see test set-up). See Design Note 009 for
further information. The fundamental switching frequency is
320 kHz for PKU 4511 PI @ V
Conducted EMI Input terminal value (typ)
EMI without filter
External filter (class B)
Required external input filter in order to meet class B in
EN 55022, CISPR 22 and FCC part 15J.
EMI with filter
Prepared (also subject responsible if other)
EJUNGYA
Approved
SEC/D (Julia You)
PKU 4000 Series
DC/DC converters, Input 36-75 V, Output 25 A/50 W
C1
L1
C3
C4
C2
L2
C5
C6
D C/D C
I
= 53 V, max I
Load
Filter components:
C1, 2, 6 = 1 µF/100 V
Ceramic
C3, 4 = 2.2 nF/1500 V
Ceramic
C5 = 100 µF/100 V
Electrolytic
L1,L2 = 1.47 mH
2.8 A, Common Mode
O
.
Checked
EQUENXU
PRODUCT SPECIFICATION
No.
3/1301-BMR 602 Uen
Date
2008-6-10
Test set-up
Layout recommendation
The radiated EMI performance of the DC/DC converter will
depend on the PCB layout and ground layer design.
It is also important to consider the stand-off of the DC/DC
converter.
If a ground layer is used, it should be connected to the output
of the DC/DC converter and the equipment ground or
chassis.
A ground layer will increase the stray capacitance in the PCB
and improve the high frequency EMC performance.
Output ripple and noise
Output ripple and noise measured according to figure below.
See Design Note 022 for detailed information.
Output ripple and noise test setup
Technical Specifi cation
EN/LZT 146 308 R4B July 2008
© Ericsson Power Modules AB
Rev
F
Reference
1 (6)
29

Related parts for PKU4513PI