H7CX-AWD1-N DC12-24 AC24 Omron, H7CX-AWD1-N DC12-24 AC24 Datasheet - Page 21

Tachometers CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr

H7CX-AWD1-N DC12-24 AC24

Manufacturer Part Number
H7CX-AWD1-N DC12-24 AC24
Description
Tachometers CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr
Manufacturer
Omron
Type
1 or 2 State, Total and Preset Counterbatch, Dual/Twin Counterr
Datasheet

Specifications of H7CX-AWD1-N DC12-24 AC24

Frequency Response
50 Hz
Product
Panel Mount Tachometer
Voltage
12 VDC to 24 VDC, 24 VAC
Display Type
6 Digit
Accuracy
+/- 0.1 %
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXAWD1NDC1224/AC24
Input Modes and Present Value (See note 1.)
I/O Functions for Counter Operation
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
* Counting starts when the CP1 is turned ON after turning ON the power.
A
A
A
B
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be at least 1/2 the minimum signal width. (See note 2.)
Present value
Present value
Present value
Present value
*CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
0
0
0
UP/DOWN C Quadrature Input Mode
UP/DOWN A Command Input Mode
0
B B B B
1
1
1
UP (Increment) Mode
1
2
2
2
3
3
A
Prohibit
2
A
A
2
Prohibit
2
3
1
1
A
3
A
A
4
2
2
4
5
3
3
5
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
Note: 1. If the configuration selection is set to dual counter, CP1 and
A
A
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
Present value
Present value
Present value
Symbol
Input method
2.
3. The meaning of the H and L symbols in the tables is explained
*CP1
CP2
CP1
CP2
CP1
CP2
CP2 input will operate in the same way as the count input
(CP1) of UP (increment) mode.
must be at least 1/2 the minimum signal width.
If they are less, a count error of 1 may occur.
Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz)
below.
A
H
L
must be greater than the minimum signal width and
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
n
0
n
UP/DOWN B Individual Input Mode
n 1
1
DOWN (Decrement) Mode
n 1
No-voltage input
n 2
2
(NPN input)
Short-circuit
100 s (when maximum counting speed = 5 kHz)
Open
3
A
n 2
Prohibit
2
A
Prohibit
n 3
1
H7CX-A@-N
Voltage input (PNP
1
4.5 to 30 VDC
A
n 3
0 to 2 VDC
input)
A
n 4
2
Counter
n 4
n 5
3
n 5
B
21