NCT1008DMN3R2G ON Semiconductor, NCT1008DMN3R2G Datasheet - Page 15

IC TEMP MONITOR 2CH DGTL 8-DFN

NCT1008DMN3R2G

Manufacturer Part Number
NCT1008DMN3R2G
Description
IC TEMP MONITOR 2CH DGTL 8-DFN
Manufacturer
ON Semiconductor
Datasheet

Specifications of NCT1008DMN3R2G

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 127°C, -64°C ~ 191°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
2.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-VFDFN Exposed Pad
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
2 Wire, SMBus, I2C
Digital Output - Number Of Bits
8 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.8 V
Description/function
Temperature Monitor with Series Resistance Cancellation
Supply Current
240 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NCT1008DMN3R2G
Manufacturer:
ON Semiconductor
Quantity:
2 350
Part Number:
NCT1008DMN3R2G
Manufacturer:
ON
Quantity:
2 572
(typical), signifying an open circuit between D+ and D−.
The output of this comparator is checked when a conversion
is initiated. Bit 2 of the status register (open flag) is set if a
fault is detected. If the ALERT pin is enabled, setting this
flag causes ALERT to assert low.
NCT1008, tie the D+ and D− inputs together to prevent
continuous setting of the open flag.
The NCT1008 Interrupt System
THERM. Both have different functions and behavior.
ALERT is maskable and responds to violations of software
programmed temperature limits or an open−circuit fault on
the external diode. THERM is intended as a fail−safe
interrupt output that cannot be masked.
programmed high temperature limits, or equals or exceeds
the low temperature limits, the ALERT output is asserted
low. An open−circuit fault on the external diode also causes
ALERT to assert. ALERT is reset when serviced by a master
reading its device address, provided the error condition has
gone away and the status register has been reset.
temperature exceeds the programmed THERM limits.
THERM temperature limits should normally be equal to or
greater than the high temperature limits. THERM is reset
automatically when the temperature falls back within the
THERM limit. A hysteresis value can be programmed; in
which case, THERM resets when the temperature falls to the
limit value minus the hysteresis value. This applies to both
local and remote measurement channels. The power−on
hysteresis default value is 10°C, but this can be
reprogrammed to any value after powerup.
THERM is used, for example, as an on/off controller for a
fan. The user’s system can be set up so that when THERM
asserts, a fan is switched on to cool the system. When
THERM goes high again, the fan can be switched off.
Programming a hysteresis value protects from fan jitter,
where the temperature hovers around the THERM limit, and
the fan is constantly switched.
Table 9. THERM Hysteresis
If the user does not wish to use an external sensor with the
The NCT1008 has two interrupt outputs, ALERT and
If the external or local temperature exceeds the
The THERM output asserts low if the external or local
The hysteresis loop on the THERM outputs is useful when
THERM Hysteresis
10°C
0°C
1°C
Binary Representation
0 000 0000
0 000 0001
0 000 1010
http://onsemi.com
15
operate. The ALERT output can be used as a SMBALERT
to signal to the host via the SMBus that the temperature has
risen. The user can use the THERM output to turn on a fan
to cool the system, if the temperature continues to increase.
This method ensures that there is a fail−safe mechanism to
cool the system, without the need for host intervention.
together to implement two methods of cooling the system.
In this example, the THERM2 limits are set lower than the
THERM limits. The THERM2 output is used to turn on a
fan. If the temperature continues to rise and exceeds the
THERM limits, the THERM output provides additional
cooling by throttling the CPU.
TEMPERATURE
1005C
905C
805C
705C
605C
505C
405C
ALERT
THERM
Figure 19 shows how the THERM and ALERT outputs
Figure 20 shows how THERM and THERM2 operate
If the measured temperature exceeds the high
temperature limit, the ALERT output asserts low.
If the temperature continues to increase and exceeds the
THERM limit, the THERM output asserts low. This can
be used to throttle the CPU clock or switch on a fan.
The THERM output deasserts (goes high) when the
temperature falls to THERM limit minus hysteresis. In ,
the default hysteresis value of 10°C is shown.
The ALERT output deasserts only when the
temperature has fallen below the high temperature
limit, and the master has read the device address and
cleared the status register.
Pin 6 on the NCT1008 can be configured as either an
ALERT output or as an additional THERM output.
THERM2 asserts low when the temperature exceeds the
programmed local and/or remote high temperature
limits. It is reset in the same manner as THERM and is
not maskable.
The programmed hysteresis value also applies to
THERM2.
Figure 19. Operation of the ALERT and THERM
1
2
Interrupts
3
THERM LIMIT
THERM LIMIT−HYSTERESIS
HIGH TEMP LIMIT
RESET BY MASTER
4