61-3440.4/2 EAO, 61-3440.4/2 Datasheet - Page 31

SWITCH, EMERGENCY STOP

61-3440.4/2

Manufacturer Part Number
61-3440.4/2
Description
SWITCH, EMERGENCY STOP
Manufacturer
EAO
Datasheet

Specifications of 61-3440.4/2

Mounting Hole Dia
16mm
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
VDE, UL, CSA, SEV
Behind Panel Depth
43mm
Ip/nema Rating
IP65
Panel Cutout
RoHS Compliant
For Use With
61 Series Illuminated Pushbutton Switches
Technical Data
switching system
material
mechanical characteristics
actuator with snap-action switching element
Self- cleaning, double-break, snap-action switching elements (con-
tact gap 2 x 0.5 mm).
The elements can be supplied with the following choice of switching
functions:
for illuminated pushbutton or switch actuator with 2 positions: max.
3 normally open contacts, max. 3 normally closed contacts or com-
bined
switch actuator with 3 positions:
max. 2 normally open contacts, max. 2 normally closed contacts or
combined
The switching element can be easily snapped to or dismantled from
the actuator.
actuator case
polyetherimide PEI, self-extinguishing
front bezel
polyetherimide PEI and chromium plated
front ring
of aluminium
lenses
polymethylmethacrylat PMMA, polycarbonate PC, aluminium
(mushroom head cap: polyamide PA)
material of contacts
gold-plated silver or silver
switching element
diallyl phthalate DAP, self-extinguishing, polysulfone PSU
actuating force
measured at the lens of the illuminated pushbutton:
2.7-10 N, depending on the number of switching elements
actuating torque
measured at the lever or key of the selector-or keylock switch:
2.5 - 10 Ncm, depending on the number of switching elements
actuating travel
illuminated pushbutton :3 mm
switch actuator with 2 positions:
switch actuator with 3 positions:
ambient air temperature
-25°C to +55°C
for indicators and illuminated pushbuttons mounted as a block ,
make sure the heat can escape freely
(as per DIN IEC 68-)
connection method
universal terminal (soldering-/plug-in terminal):
max. wire diameter: 2 of 1 mm
max. wire cross-section of stranded cable: 1 x 0.75 mm
ing-/plug-in terminal: 2.8 x 0.5 mm
1 x ca. 42° deflection momentary action
1 x ca. 90° deflection maintained action
2 x ca. 42° deflection momentary action
2 x ca. 90° deflection maintained action
2
solder-
electrical characteristics
degree of protection
indicator, illuminated pushbutton, emercency stop switch, selector-
and keylock switch: front IP 65
switching element IP 40
soldering terminal IP 20
mechanical life
as per IEC 512-5-6
momentary action 2 mio. cycles of operation
maintained action 1 mio. cycles of operation
keylock switch 50000 cycles of operation
selector switch 100000 cycles of operation
rebound time
<= 5ms
resistance to shock
(single impacts, semi-sinusoidal)
50 g, 11 ms as per IEC 512-4-3, IEC 68-2-27
resistance to vibration
(sinusoidal)
10 g, at 10- 2000- 10 Hz, amplitude 0.75 mm as per IEC 512-4-4,
IEC 68-2-6
storage temperature
-40°C to + 85°C
(as per DIN IEC 68-)
continuous thermal current lth
5 A
The maximum current in continuous operation and at ambient tem-
perature not exceeding the quoted maximum values.
electric strength
as per VDE 0630 (IEC 512-2-11)
2500 VAC, 50 Hz, 1 min between all terminals and earth
electrostatic breakdown value
>= 11 KV (keylock switch)
protection class
II
rated current
6 A
rated voltage
250 VAC/VDC
switch rating
gold-/silver contact:
silver contact:
switch rating AC, cos.
rated service voltage
rated service current
switch rating DC, L:R=30 ms:
rated service voltage:
rated service current
resistive:
rated service current
L:R=30ms:
volume resistance
starting value (initial) for:
gold-/silver contact <= 50 m
silver contact <= 100 m
min. 5 VAC/10 mA
max. 250 VAC/6 A
min. 20 VAC/500 mA
max. 250 VAC/6 A
0,7:
as per IEC 512-2-test 5
250 VAC
2 A
220
0.5
0.15
as per IEC 512-2-test 4
2
110
0.3
0.7
125 VAC
3 A
01.2000
60
2.0
0.7
137
110 VAC
3 A
24 VDC
6.0 A
2.0 A
61
61

Related parts for 61-3440.4/2