FD-FM2 PANASONIC EW, FD-FM2 Datasheet

PHOLOELECTRIC SENSOR

FD-FM2

Manufacturer Part Number
FD-FM2
Description
PHOLOELECTRIC SENSOR
Manufacturer
PANASONIC EW
Type
Reflectiver
Datasheet

Specifications of FD-FM2

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PHOTOELECTRIC SENSOR
DIGITAL FIBER SENSOR
FX-300
SERIES
Conforming to
UL Recognition
EMC Directive
Constant advances achieving the highest
level of performance in its class

Related parts for FD-FM2

FD-FM2 Summary of contents

Page 1

Constant advances achieving the highest level of performance in its class PHOTOELECTRIC SENSOR DIGITAL FIBER SENSOR FX-300 Conforming to EMC Directive SERIES UL Recognition ...

Page 2

The FX-300 series of next-generation fiber sensors provides the highest level of sensing performance in its class ‘Stable sensing’, ‘high sensing performance’, ‘easy operation’, ‘improved ease of maintenance’ and ‘preservation of the environment’ are the five concepts underlying the new ...

Page 3

APC circuit has been added, in addition to the four-chemical emitting element. Concept 1 High Stability Concept 5 Eco-friendly Lead-free solder used is gentle on the environment. Full range of fibers Guide for each industry P.9 LCD • Semiconductor / ...

Page 4

High Stability Double coupling lens Stable sensing over long and short periods In addition to a ‘four-chemical emitting element’ which suppresses changes in the light emitting element over time so that a stable level of light emission can be maintained ...

Page 5

Superior Performance Light-emitting amount selection If the light receiving level becomes saturated during close- range sensing or when sensing transparent or minute objects, you can adjust the light emitting amount of the sensor to stabilize sensing without needing to change ...

Page 6

Superior Performance Simplified systems using new operating modes A window comparator mode and differential sensing mode have been added. These modes make it easy to carry out sensing tasks that previously required multiple sensors or involved complex threshold settings. ● ...

Page 7

Easy operation Operation indicator Stability indicator Even beginners can quickly learn how to use the MODE NAVI MODE NAVI uses six RUNn RUN This is the sensing mode. indicators to display the TEACH Incident light level is displayed in the ...

Page 8

Easy Maintenance Communication unit improves equipment starting up and maintenance upstream communication unit SC-GU1-485 The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching carried out via a PLC, and also ...

Page 9

Wiring- and labor-saving design allows side- by-side configuration for up to sixteen units FX-301/B/G/H One unit can be used as either a main unit or sub unit The amplifier unit can be used as either a main unit or a ...

Page 10

... Aperture angle 2 FT-WKV8, FT-KV8 Aperture angle for the ultra-narrow optical beam less. The light does not spread much at all, so that stable sensing can be obtained. FT-H , FD-H Glass substrate detection Heat-resistant 350 C 662 F FD-H35-M2 Can be used in temperatures ranging from 60 to 350 662 F ...

Page 11

... Large display with 4 digits (9999). Extremely fine settings for detecting minute changes can be made to provide more stable sensing for items such as transparent objects. Contact type liquid level detection fiber FD-F8Y Resist tank Around liquids • Chemical-resistant fiber Chemical-resistant fiber with fluorine resin coatings over the whole of the fiber, leak detection fiber that quickly sense leaks such as from detergents, and liquid detection fiber that accurately sense liquid levels are among the lineup of fibers that are ideal for liquid sensing ...

Page 12

... Actual digit difference Upper display limit 4000 B Saturated digit difference: D Affects positioning precision Cost and man-hour inefficiencies Man-hour and space inefficiencies FD-L40 series, FR-WKZ11 FD-L46 Seating confirmation / Convergent reflective type FD-L44 Long sensing range 0.236 in for seating confirmation. FX-301 FX-301-HS [Stable sensing] Light emitting Actual digit difference: C’ ...

Page 13

FOR LCD • SEMICONDUCTOR INDUSTRY External data bank switching and teaching are possible The FX-CH2 external input unit (optional) can be used to carry out teaching and data bank switching operations externally without needing to operate the digital fiber sensors ...

Page 14

... Screw length discrimination [ Distinguishing between sensing objects A, B and C Ultra high-speed response 35¨ window comparator mode for distinguishing between sensing objects with single output is also available. FD-FM2 IP-2 130 !s 300 !s 500 !s 1 Output 1 and output 2 can be used together to distinguish between sensing objects A, B and C. ...

Page 15

... FD-EG1 7.5 0.5 mm 0.295 0.020 in approx. "0.5 mm "0.020 in FD-WG4/G4/G6X/G6 7.5 0.5 mm 0.295 0.020 in approx. Ultra small diameter fiber Sleeve head diameter of 0.25 mm 0.010 in has been realized (FT-E12). This has improved the sensing capability for minute objects such as the 0603 chip. ...

Page 16

... FR-WKZ11, FR-KZ21/22 H5.2 D15 mm W0.374 H0.205 D0.591 R0.039 in making it space efficient. FT-V10 Chemical-resistant fiber With the case made of PFA (fluorine resin) and fiber sheath with PFA (fluorine resin), the fiber can be used with various types of chemical liquids. FT-P81X, FD-P81X, FD-G6X in. FT-Z802Y ...

Page 17

ORDER GUIDE Connector type amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Appearance Model No. FX-301 FX-301P FX-301B FX-301BP FX-301G FX-301GP FX-301H FX-301HP FX-301-HS FX-301P-HS FX-305 FX-305P Emitting element Output Type NPN open-collector transistor ...

Page 18

FX-300 ORDER GUIDE Quick-connection cables Quick-connection cable is not supplied with the amplifier. Please order it separately. For FX-301(-HS)/B/G/H Type Model No. CN-73-C1 Length Main cable CN-73-C2 Length (3-core) CN-73-C5 Length CN-71-C1 Length: 1 ...

Page 19

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) Lens mountable M4 Lens mountable M4 Sleeve 90 mm 3.543 ...

Page 20

FX-300 LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) With lens Long sensing range "3 "0.118 "3 "0.118 ...

Page 21

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) Easy mounting Top sensing W3 H8 D12 W0.118 H0.315 D0.472 ...

Page 22

FX-300 LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) 350 C 662 F Lens mountable M4 350 C ...

Page 23

... Model No. : S-D radius (Note 4) : Free-cut 6.299 FD-B8 R25 mm R0.984 in FD-FM2 Fiber FD-FM2S R25 mm R0.984 Sleeve "0.02 mm 6.562 ft "0.0008 in R10 mm FD-FM2S4 R0.394 in gold wire R1 mm FD-W8 R0.039 R0.157 in FD-P80 Flexible 1 m R10 mm FD-P81X 3.281 ft R0.394 in "0.02 mm R25 mm "0.0008 in FD-R80 2 m R0.984 in gold wire 6 ...

Page 24

... Notes: 1) Refer to p.27 for the sensing ranges for the FX-301-HS in H-SP mode and for the FX-301B/G/H. 2) The sensing range is specified for white non-glossy paper [200 FD-WT4, FD-P40, FD-G6, FD-EG1, FD-EG2, FD-EG3, FD-EN500S1, FD-ENM1S1: 100 3) Please take care that the sensing range of the free-cut type fiber may be reduced max. depending upon how the fiber is cut. ...

Page 25

... W0.283 H0.295 D0.079 1 to 5.5 0.039 to 0.217 Notes: 1) Refer to p.27 for the sensing ranges for the FX-301-HS in H-SP mode and for the FX-301B/G/H. 2) The sensing range is specified for white non-glossy paper (FD-S80, FD-WS8: 400 FD-SFM2SV2: 200 200 mm 7.874 7.874 100 100 t 0 ...

Page 26

... R0.984 in 6.562 ft gold wire Protective tube R40 R1.575 in Fiber 6.562 ft R15 mm (Note 5) R0.591 in (Liquid) 0.039 to 0.118 in] R10 R0.394 in 6.562 ft 0.039 in] (FD-WKZ1, FD-AFM2, FD-AFM2E: 400 400 mm 15.478 Model No. FD-WZ4 FD-WZ4HB FD-WZ7 FD-WZ7HB FD-WKZ1 FD-A15 FD-AFM2 FD-AFM2E FD-F8Y FD-F41 FD-F4 15.478 in)] ...

Page 27

... Notes: 1) Refer to p.27 for the sensing ranges for the FX-301-HS in H-SP mode and for the FX-301B/G/H. 2) The sensing range is specified for white non-glossy paper [400 glass substrate, FD-H30-KZ1V-S, FD-H30-L32V-S: 100 3) Please take care that the sensing range of the free-cut type fiber may be reduced max. depending upon how the fiber is cut. ...

Page 28

... FX-301H 50 1.969 25 STD (Note) FAST 30 1.181 18 Note: Infrared types are easily affected by humidity using them in environments with high humidity or where the humidity fluctuates, please contact our office. FD-B8 FD-FM2 FD-NFM2 FD-W8 80 3.150 46 LONG FX-301B STD 40 1.575 23 26 1.024 15 FAST 42 1 ...

Page 29

... LONG STDF STD FAST S-D H-SP 1,200 650 450 300 150 200 62.992 in). • Applicable fibers: FD-WG4, FD-G4 0.039 158 F Sensing range for red LED type (Note) Screw-in depth Distance to focal point Spot diameter "0 18.5 mm approx. "1 approx "2 approx ...

Page 30

... FT-NFM2S4 steel, protects the inner ft) fiber FD-B8 FD-P80 For external forces. FD-FM2 FT-H13-FM2 M6 ft) FD-FM2S thread FD-FM2S4 ft) ft) FD-T80 For FD-NFM2 M4 ft) FD-NFM2S thread FD-NFM2S4 ft) The fiber bender bends the sleeve part of the fiber head at the proper radius. (Note) Horizontal mounting type ...

Page 31

SPECIFICATIONS Type Red LED NPN output FX-301 PNP output FX-301P Item Supply voltage < Red LED / Infrared LED type Power consumption Normal operation: 960 mW or less (Current consumption less supply voltage) ECO ...

Page 32

FX-300 I/O CIRCUIT DIAGRAMS FX-301(-HS) NPN output type Color code D (Brown) V (Note 1) Load (Black) Output Tr 100 mA max. (Note (Blue (Note 1) Internal circuit Users’ circuit Notes: 1) The quick-connection sub ...

Page 33

... Detection may become unstable. Please refer to the ‘Sensor general catalog 2003-2004’ or website (http://www.sunx.jp) for setting of threshold value when used in combination with contact type liquid level detection fiber FD-F8Y, and for ’ blinks. setting of threshold value when used in combination with pipe-mountable liquid level detection fiber FD-F4 ...

Page 34

FX-300 PRECAUTIONS FOR PROPER USE Threshold value fine adjustment Step Description Press the MODE key to light up MODE indicator / ADJ (yellow). 1 For the FX-305(P), select ‘ ’ or ‘ In case the threshold value ...

Page 35

PRECAUTIONS FOR PROPER USE Function table for FX-300 series FX-301(P) (Previous version unit) Four-chemical emitting element APC circuit g Four-chemical emitting element only Light emitting amount selection function g Reduced intensity mode (S-D) 9,999 digit display 150 !s Response time ...

Page 36

FX-300 DIMENSIONS (Unit: mm in) FX-301 Amplifier FX-305 Notes: 1) FX-305 ; Output 1 operation indicator (Orange) 2) FX-305 ; Output 2 operation indicator (Orange) 3) FX-301 ; 3-pin, FX-305 ; 4-pin CN-73-C Main cable (Optional) CN-74-C • Length (L) ...

Page 37

External Input Unit for Digital Sensor / FX-CH2 Conforming to EMC Directive Support for stable sensing and smooth setup changes! Teaching and data bank switching for maximum of 16 digital fiber sensors (FX-301 and FX-305) can be ...

Page 38

ORDER GUIDE Designation NPN input type External input unit PNP input type Connector for input device (1 pc. included as standard with external input unit) Length Quick-connection cable Length (Main cable) Length End plate ...

Page 39

Upper Communication Unit for Digital Sensors / SC-GU1-485 Conforming to EMC Directive We now offer remote maintenance for sensors! Also reduces the work required to the system to start running! Centralized control and setting of scattered digital sensors (FX-301/305) is ...

Page 40

SPECIFICATIONS Type Main unit Item Model No. SC-GU1-485 Applicable sensor FX-301(P)(Note), FX-305(P) Connectable units Max. 16 units of sensor per SC-GU1-485 Connectable nodes Max. 31 nodes Supply voltage Ripple P-P10 % or less Current consumption ...

Related keywords