FD-FM2 PANASONIC EW, FD-FM2 Datasheet - Page 37

PHOLOELECTRIC SENSOR

FD-FM2

Manufacturer Part Number
FD-FM2
Description
PHOLOELECTRIC SENSOR
Manufacturer
PANASONIC EW
Type
Reflectiver
Datasheet

Specifications of FD-FM2

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Support for stable sensing and
smooth setup changes!
Teaching and data bank switching for up to a maximum of
16 digital fiber sensors (FX-301 and FX-305) can be
carried out all at once using an external device such as a
PLC, touch screen or switch.
Digital fiber settings can be changed using input from a touch screen or switch, so that
production line setup changes can be carried out more easily.
Connector for input device
CN-EP1 [1 pc. included with FX-CH2(-P)]
• Input signal
Teaching input
External Input Unit for Digital Sensor / FX-CH2
FX-CH2 function list
Product lineup
Explanation of limit teaching
The
operations are deter-
mined by S1 and S2,
and the input timing is
determined by S3.
The following types of external teaching can be carried out.
● Full-auto teaching ● Limit teaching ‘
● Limit teaching ‘
If the incident light intensity changes with
respect to the initial threshold setting value
because of reasons such as beam axis
slippage, sensing can become unstable
and incorrect operations can occur.
External teaching
Data bank switching
Full-auto teaching is recommended for teaching when the sensing object is changed
without stopping the line.
Settings such as output operations (L-ON / D-ON) and timer operations can be recorded
in the digital fiber sensor’s data bank and switching can be carried out externally.
m Up to 3 files can be stored.
Limit teaching ‘
less than the incident light intensity during teaching.
When limit teaching is not used
● Limit teaching ‘
EMC Directive
Conforming to
Setup changes
Threshold
value
Threshold value setting
types
Initial setting
Incident light intensity when sensing
object is not present
Unstable sensing
of
Pass 1
input
Sensing not possible
’ shifts the threshold value setting to make it
’ ● 2-level teaching
Pass 2
Applications involving smooth setup operations
m FX-CH2(-P) does not include a cable
(external automatic teaching / data bank switching)
COM.
ON
OFF
for connecting to the input device.
Time
S1
S2
S3
The threshold value is reset each
time before the sensing object
arrives, (limit teaching ‘
result, sensing is not affected by
changes in incident light intensity.
When limit teaching ‘
Threshold value setting
Initial setting
Threshold
value
Incident light intensity when sensing
object is present
Threshold value resetting
Pass 1
Threshold value resetting again
Pass 2
External input unit FX-CH2(-P)
Shift amount
’ is used
’). As a
OFF
ON
Time
Key lock setting input
Data bank switching input
The key lock function that prevents incorrect operations by operators can
be set on and off.
Switching between 3 channels of data banks and loading and saving of
all channels at once can be carried out.
m When limit teaching is used, use the SHIFT function in PRO mode of
● Limit teaching ‘
Limit teaching ‘
the threshold value setting is shifted toward a higher setting to
make it more than the incident light intensity during teaching.
If dust or other particles cause changes
in the incident light intensity with
respect to the initial threshold setting
value, sensing can become unstable
and incorrect operations can occur.
When limit teaching is not used
the amplifier to set the shift amount beforehand.
Threshold
value
Threshold value setting
Initial setting
Unstable sensing
Pass 1
’ is the opposite of limit teaching ‘
Sensing not possible
Pass 2
Quick-connection cable
CN-73-C
OFF
ON
Time
The threshold value is reset each
time before the sensing object
arrives, (limit teaching ‘
result, sensing is not affected by
changes in incident light intensity.
When limit teaching ‘
(Optional)
Threshold value setting
MODE
0V
Initial setting
V
Threshold
value
• Mode selection
The MODE wire can be
switched between high and low
to select the input mode from
either ‘external teaching and key
lock’ or ‘data bank switching’.
Threshold value resetting
Pass 1
Threshold value resetting again
Pass 2
’ is used
’, so that
Shift amount
’). As a
OFF
ON
Time
36

Related parts for FD-FM2