D10INFP BANNER ENGINEERING, D10INFP Datasheet

Photoelectric Sensor

D10INFP

Manufacturer Part Number
D10INFP
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Analog And Discrete Outputr
Datasheet

Specifications of D10INFP

Sensor Output
NPN
Contact Current Max
150mA
Switch Terminals
Connector
Peak Reflow Compatible (260 C)
No
Sensor Input
Fiber Optic
Output Type
Transistor
Leaded Process Compatible
No
Fiber Optic Sensor Type
Analog And Discrete Output
Printed in USA
* 9 m (30
A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety
Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
D10INFP
D10INFPQ
D10IPFP
D10IPFPQ
D10UNFP
D10UNFPQ
D10UPFP
D10UPFPQ
A model with a QD connector requires a mating cable (see page 15).
!
Red Beam
'
) cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., D10INFP W/30).
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications.
Models
D10INFPG
D10INFPGQ
D10IPFPG
D10IPFPGQ
D10UNFPG
D10UNFPGQ
D10UPFPG
D10UPFPGQ
Green Beam
Not To Be Used for Personnel Protection
• Easy-to-set automatic Expert-style TEACH options* including static, dynamic, and
• 16-bit microcontroller and 12-bit Analog-to-Digital converter for high-performance,
• Easy-to-read 4-digit display for TEACH and signal strength readout, plus indicators
• Models available with one scalable Analog output (4-20 mA or 0-10V) and one
• Four-mode power and speed selection with automatic cross-talk avoidance circuitry
• Selectable OFF-delay options
• Gate input wire can be used to selectively inhibit sensor outputs from switching
• Models available with visible red (680 nm) or visible green (525 nm) sensing beam
• Models available with 2 m or 9 m (6.5' or 30') cable or integral Pico-style
• Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail
* U.S. Patent #5,808,296
D10 Expert
Advanced sensor for use with plastic fiber optics
single-point programming plus manual adjustment for fine-tuning
low-contrast sensing
for a continuous readout of operating status (user configurable)
Discrete output (PNP or NPN)
quick-disconnect
6-pin Pico-style QD
6-pin Pico-style QD
6-pin Pico-style QD
6-pin Pico-style QD
2 m (6.5') Cable
2 m (6.5') Cable
2 m (6.5') Cable
2 m (6.5') Cable
Cables*
Models
02/04
Analog and Discrete Outputs
Features
Discrete Outputs
NPN
NPN
PNP
PNP
Analog Output
4-20 mA
P/N 65448 rev. E
0-10V

Related parts for D10INFP

D10INFP Summary of contents

Page 1

... D10UPFPG D10UPFPQ D10UPFPGQ ' * 9 m (30 ) cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., D10INFP W/30). A model with a QD connector requires a mating cable (see page 15). WARNING . . . ! Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. ...

Page 2

... Maximum power setting • Analog: full scale • Discrete: switchpoint positioned at middle of range Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 Green 525 180 mm 320 mm 3 100 mm ...

Page 3

... Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert Analog and Discrete Outputs ™ Sensor Programming Programming Procedures Two push buttons, Dynamic (+) and Static (-), may be used to access and set programming parameters. For remote programming, connect a switch or digital input to the gray wire ...

Page 4

... Models Models 20 mA 10V Light Figure 3. Analog output as a function of target position – single-point TEACH Voltage-Sourcing Models 10V dc LO Slope Single Point 5V dc Taught DO Slope 0V dc Max. Max. Dark Light Signal Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 5

... Selects which channel to teach • Displays channel configuration information. Push Button • Single-click both buttons simultaneously. Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert ™ Active Channel Select Remote 0.04 sec. ≤ T ≤ 0.8 sec. • Triple-pulse the remote line ...

Page 6

... Arrow icon remains red • After 60 seconds, sensor returns to RUN mode (Arrow icon turns green) without changing settings. Result Contrast Values 500+ Excellent 100 - 500 Good Low Marginal Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 7

... Push Button • Press and hold Dynamic (+) button. • Present Output ON/OFF conditions while continuing to hold Dynamic button. • Release Dynamic button. Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert ™ Dynamic TEACH Remote • Hold remote line • ...

Page 8

... Arrow icon remains red • After 60 seconds, sensor returns to RUN mode (Arrow icon turns green) without changing settings. Result the threshold setpoint value being changed “dec” as single-point tolerance is adjusted. or Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 9

... Click Dynamic (+) to toggle between selections. • Click Static (-) to save selection and return to RUN mode. Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert Analog and Discrete Outputs ™ Sensor Setup • Click Dynamic (+) or double-pulse remote line to select an option. ...

Page 10

... Padlock icon appears between selections. • Sensor remains in RUN mode Push Buttons Enabled: • Display flashes “uloc” • Padlock icon disappears • Sensor remains in RUN mode T Result Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 11

... Click Static (-) to advance to “Display Orientation.” • Click Dynamic (+) to toggle between selections. • Click Static (-) to return to RUN mode. Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert Analog and Discrete Outputs ™ Advanced Setup T T Remote 0.04 sec. ≤ T ≤ 0.8 sec. ...

Page 12

... This feature is useful for controlling when the outputs are allowed to change states. Gate input function response time is 1 millisecond. 12 P/N 65448 rev. E Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 13

... Temperature: -20° to +55°C (-4° to +131°F) Storage Temperature: -20° to +80°C (-4° to +175°F) Max. Rel. Humidity: 90% @ 50°C (non-condensing) Installation 35 mm DIN rail or included mounting bracket Certifications Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert Analog and Discrete Outputs ™ Specifications NPN < ...

Page 14

... Plastic Fiber Emitter Port Plastic Fiber Receiver Port 9.8 mm (0.39") M3 Hardware included: 8.6 mm (0.34") Lock Washer (2) Flat Washer (2) Screws (2) 5.0 mm (0.20") Hex Nuts (2) 2.5 mm (0.10") 25.4 mm (1.00" ø3.3 mm (0.13") 2x ø3.2 mm (0.13") Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 ...

Page 15

... Voltage Rating: 30V ac/36V dc Style Model Length PKG6Z (6.5') 6-Pin Straight PKG6Z (30') PKW6Z (6.5') 6-Pin Right-angle PKW6Z (30') Minneapolis, MN U.S.A. Banner Engineering Corp. • www.bannerengineering.com • Tel: 763.544.3164 D10 Expert Analog and Discrete Outputs ™ Hookups – 12-24V Teach Gate + 12-24V dc – ...

Page 16

... Analog and Discrete Outputs ™ WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period ...