D10UPFP BANNER ENGINEERING, D10UPFP Datasheet - Page 3

Photoelectric Sensor

D10UPFP

Manufacturer Part Number
D10UPFP
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Analog And Discrete Outputr
Datasheets

Specifications of D10UPFP

Sensor Output
PNP
Peak Reflow Compatible (260 C)
No
Sensor Input
Fiber Optic
Output Type
Transistor
Leaded Process Compatible
No
Contact Current Max
150mA
Brand/series
D10 Expert™
Current, Switching
150 mA
Function
Fiber Optic
Ip Rating
IP50
Mounting Type
DIN Rail
Output
PNP/Voltage
Primary Type
Photoelectric
Sensing Mode
Selectable
Technology
Photoelectric
Termination
6-Wire Cable
Voltage, Supply
24 VDC
Accessories Available
Cordsets and Plastic Fiber Optic Cable
Fiber Optic Sensor Type
Analog And Discrete Output
D10 Expert
Analog and Discrete Outputs
Sensor Programming
Programming Procedures
Two push buttons, Dynamic (+) and Static (-), may be used to access and set
programming parameters. For remote programming, connect a switch or digital input
to the gray wire; length of the individual pulses is equal to the value T:
0.04 seconds ≤ T ≤ 0.8 seconds
Returning to RUN mode
TEACH and SETUP modes each may be exited in one of two ways: by exercising the
60-second time-out, or by cancelling out of the process. In TEACH mode, the sensor
will return to RUN mode without saving any of the new settings; in SETUP mode, the
sensor will return to RUN mode but save all of the settings. To cancel out of TEACH
mode, press and hold the Static (-) button for 2 seconds; to cancel out of SETUP
mode, press and hold both the Static (-) and Dynamic (+) buttons for 2 seconds.
Output 2
The setpoint(s) for each output can be set independently of one another. However, the
functional range available for output 2 is dictated by the automatic power and gain
settings established for output 1. Whenever output 1 is taught, output 2 also must be
retaught. Applications hint: teach the weakest signal on output 1 first.
Dynamic TEACH and Adaptive Thresholds
Dynamic TEACH is used to program sensitivity during actual machine run conditions.
During Dynamic TEACH, the sensor takes multiple samples of the light and dark
conditions and automatically sets the sensitivity at the optimum level. For the discrete
output, Dynamic TEACH activates the sensor’s adaptive threshold system, which
continuously tracks minimum and maximum signal levels, and automatically maintains
centering of the switch point between the light and dark conditions. The adaptive
threshold system remains in effect during RUN mode to automatically adjust for
changes in the light or the dark conditions.
When Dynamic TEACH mode is used to program sensitivity, the output ON state (light
or dark operate) will remain as it was last programmed. To change to either light or
dark operate, use the SETUP mode (see page 9).
Sensitivity may be adjusted at any time when the sensor is in RUN mode by clicking
the “+” and “-” buttons. However, when a manual adjustment is made, the adaptive
threshold system is disabled (cancelled).
Minneapolis, MN U.S.A.
Banner Engineering Corp.
3
www.bannerengineering.com • Tel: 763.544.3164
P/N 65448 rev. E

Related parts for D10UPFP