XDP4/I(400V50HZ) MOELLER, XDP4/I(400V50HZ) Datasheet

STARTER, DOL, ISOLATOR, PLASTIC

XDP4/I(400V50HZ)

Manufacturer Part Number
XDP4/I(400V50HZ)
Description
STARTER, DOL, ISOLATOR, PLASTIC
Manufacturer
MOELLER
Datasheet

Specifications of XDP4/I(400V50HZ)

Supply Voltage Range
400V
No. Of Phases
Three
Power Rating
4kW
Current Rating
8.5A
Svhc
No SVHC (18-Jun-2010)
Contact Voltage Ac Nom
400VAC
External Depth
160mm
External Length / Height
222mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
This document applies to following Moeller Electric Motor Starters:
Where (*,*) refers to the available coil voltage; either (230V 50Hz, 240V 60Hz) or (400V 50Hz, 440V 60Hz)
This product should be installed, commissioned and maintained by a competent person in accordance with these instructions, and the
appropriate clauses of the current edition of the IEE Wiring Regulations (BS 7671).
It is essential that the mains electricity supply that will be, or is currently, connected to this product is isolated before commencing work.
All connections should be made to the product as instructed; field cables should not be stressed, and terminal screws should be fully
tightened to the recommended torque values.
To avoid risk of fire, do not exceed the maximum rated current of this product.
Please ensure that these instructions are left with the person responsible for the future operation and maintenance of this product.
Motor Starters supplied in insulated enclosures are “Totally Insulated” in accordance with BS EN 60439-1:1999.
The insulating material that therefore encapsulates all the electrical apparatus must not be pierced by conducting parts such as metal
screws, conduit, cable glands, etc. (See BS7671. IEE Regs. 413-03)
The metal mounting plate and other exposed conductive parts within the enclosure are therefore not earthed.
For conduit entry, insulated conduit fittings must be used for attaching plastic or metal conduit to the enclosure, thus avoiding metallic
penetration of the enclosure wall.
Where cable entry to the Motor Starter is required to be via metal trunking, this shall be done by insulated conduit fittings. Alternatively,
where the enclosure is to be butted up to the trunking, an opening should be cut into the wall of the trunking to clear the insulated
grommets or glands that must be fitted to the enclosure openings (knockouts). The enclosure must not be attached to the trunking itself
unless screws of insulating materials are used.
Motor Starters supplied in insulated enclosures with transparent polycarbonate lids are recommended to be occasionally cleaned with
an anti-static cleaning cream/polish; on no account should these covers be cleaned with any chemical solvent, such as trichlorethylene,
acetone, varnish thinner or liquid fuel.
These products are supplied without an Overload Relay.
An Overload Relay must be fitted and wired to the Contactor Q11 and the flying leads terminated, as
indicated elsewhere in this document, before the starter is put into service.
DANGER OF DEATH exists if this instruction is not followed.
(with Isolator)
Motor Starter
Direct-on-Line
Direct-on-Line
Reversing
Star-Delta
(P) refers to types with an Incoming Supply Isolator
Stainless Steel
Stainless Steel
Stainless Steel
Enclosure
Insulated
Insulated
Insulated
Material
Steel
Steel
Steel
Installation and Commissioning Instructions
XDR(P)4/ST (*,*)
XDR(P)4/SS (*,*)
IMPORTANT SAFETY INSTRUCTIONS – PLEASE READ
XD(P)4/SS (*,*)
XD(P)4/ST (*,*)
XDR(P)4/I (*,*)
XD(P)4/I (*,*)
4kW
Notes Specific to Insulated Enclosures
Enclosed Motor Starters
XDR(P)5.5/SS (*,*)
XDR(P)5.5/ST (*,*)
XSD(P)5.5/ST (*,*)
XSD(P)5.5/SS (*,*)
XD(P)5.5/ST (*,*)
XD(P)5.5/SS (*,*)
XDR(P)5.5/I (*,*)
XSD(P)5.5/I (*,*)
XD(P)5.5/I (*,*)
5.5kW
AC-3 400V Rating
XDR(P)7.5/ST (*,*)
XDR(P)7.5/SS (*,*)
XSD(P)7.5/SS (*,*)
XSD(P)7.5/ST (*,*)
XD(P)7.5/ST (*,*)
XD(P)7.5/SS (*,*)
XDR(P)7.5/I (*,*)
XSD(P)7.5/I (*,*)
XD(P)7.5/I (*,*)
7.5kW
XSD(P)11/ST (*,*)
XSD(P)11/SS (*,*)
XD(P)11/ST (*,*)
XD(P)11/SS (*,*)
XSD(P)11/I (*,*)
XD(P)11/I (*,*)
11kW
XSD(P)15/SS (*,*)
XSD(P)15/ST (*,*)
XSD(P)15/I (*,*)
15kW

Related parts for XDP4/I(400V50HZ)

XDP4/I(400V50HZ) Summary of contents

Page 1

... Installation and Commissioning Instructions This document applies to following Moeller Electric Motor Starters: Motor Starter Enclosure (with Isolator) Material Insulated XD(P)4/I (*,*) Direct-on-Line Steel XD(P)4/ST (*,*) Stainless Steel XD(P)4/SS (*,*) Insulated XDR(P)4/I (*,*) Reversing Steel XDR(P)4/ST (*,*) Direct-on-Line Stainless Steel XDR(P)4/SS (*,*) Insulated Star-Delta Steel Stainless Steel Where (*,*) refers to the available coil voltage; either (230V 50Hz, 240V 60Hz) or (400V 50Hz, 440V 60Hz) (P) refers to types with an Incoming Supply Isolator IMPORTANT SAFETY INSTRUCTIONS – ...

Page 2

One of these circuit diagrams will apply to this Motor Starter; please note that hatched areas represent the installation of, and final control circuit connections to, the Overload Relay which is available separately. The dotted box around Q1 represents when ...

Page 3

... The dial should be turned so that the full load current of the motor (obtained from the motor rating label) lines up with the pointer below the dial. Note that for star-delta motor starters (XSD…), where the overload is connected in the motor supply cables, the dial should be set to 0.58 x FLC see table below. ...

Page 4

... Check that contactor(s) are free from dust and foreign bodies before energising motor starter. Never lubricate or grease contacts, sliding guides or magnet armatures. For alternative voltages and options please refer to Moeller Technical Support, who are also able to quote for the complete KeyBuild range of Starters, Distribution Boards and Custom Control Panels. ...

Related keywords