Specifications of S701D03N3S

No. Of Phases
Three
Power Rating
1.1kW
Current Rating
3.5A
Peak Reflow Compatible (260 C)
No
Output Current
3.5A
Supply Voltage Max
415VAC
Control Voltage Max
415V
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Technical Data and Specifications
Soft Starters—S701_03N3S
Description
Maximum current capacity
Trip Class
Electrical Characteristics
Line voltage (Vac)
Operating frequency (Hz)
Leakage current
Minimum operational current
Control voltage (Vac/Vdc)
Pickup voltage max.
Dropout voltage min.
Max. control current for no operation
Response time max.
Control Characteristics
Ramp time (secs)
Ramp settings (% LRT)
Kick start settings (% LRT)
Soft stop (secs)
Environment Characteristics
Temperature–operating (no derating)
Current rating 50°C
Limited duty cycle 50°C
Current rating 60°C
Limited duty cycle 60°C
Temperature–storage
Altitude (meters)–no derating
Humidity
Operating position (no derating)
Impulse withstand voltage IEC 947-4-1
Rated insulation voltage (Ui)
Installation category
Vibration
Power dissipation for intermittent operation
Power dissipation for continuous operation
Cooling method
Degree of protection
Pollution degree
Agency approvals
10A
10
20
30
S701C03N3S
3.5
3.5
3.5
2.8
2.1
208–240
50/60
5 mA AC max.
50 mA
24–240
20.4 Vac/Vdc
5 Vac/Vdc
1 mA
70 ms
0.5–10
85%
85%
0.5–10
–30° to 40°C
N/A
N/A
N/A
N/A
–30° to 80°C
2000
95% noncondensing
Vertical ±30°
4000V
660V
III
IEC 68-2-6 5g 10–150 Hz
4 W/A x duty cycle
4 W/A x duty cycle
Natural convection
IP20
3
UL, cUL, CE
Control Products Catalog CA08102001E—September 2010 www.eaton.com
Reduced Voltage Motor Starters
S701D03N3S
3.5
3.5
3.5
2.8
2.1
380–415
50/60
5 mA AC max.
50 mA
24–300
20.4 Vac/Vdc
5 Vac/Vdc
1 mA
70 ms
0.5–10
85%
85%
0.5–10
–30° to 40°C
N/A
N/A
N/A
N/A
–30° to 80°C
2000
95% noncondensing
Vertical ±30°
4000V
660V
III
IEC 68-2-6 5g 10–150 Hz
4 W/A x duty cycle
4 W/A x duty cycle
Natural convection
IP20
3
UL, cUL, CE
S701E03N3S
3.5
3.5
3.5
2.8
2.1
440–480
50/60
5 mA AC max.
50 mA
24–300
20.4 Vac/Vdc
5 Vac/Vdc
1 mA
70 ms
0.5–10
85%
85%
0.5–10
–30° to 40°C
N/A
N/A
N/A
N/A
–30° to 80°C
2000
95% noncondensing
Vertical ±30°
4000V
660V
III
IEC 68-2-6 5g 10–150 Hz
4 W/A x duty cycle
4 W/A x duty cycle
Natural convection
IP20
3
UL, cUL, CE
Solid-State Controllers
S701G03N3S
3.5
3.5
3.5
2.8
2.1
500–600
50/60
5 mA AC max.
50 mA
24–300
20.4 Vac/Vdc
5 Vac/Vdc
1 mA
70 ms
0.5–10
85%
85%
0.5–10
–30° to 40°C
N/A
N/A
N/A
N/A
–30° to 80°C
2000
95% noncondensing
Vertical ±30°
4000V
660V
III
IEC 68-2-6 5g 10–150 Hz
4 W/A x duty cycle
4 W/A x duty cycle
Natural convection
IP20
3
UL, cUL, CE
39.1
5
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39