SY114-6LOU-Q SMC Corporation of America, SY114-6LOU-Q Datasheet

no-image

SY114-6LOU-Q

Manufacturer Part Number
SY114-6LOU-Q
Description
VALVE, 3 PORT, CLOSED, 12DC
Manufacturer
SMC Corporation of America
Datasheet

Specifications of SY114-6LOU-Q

Supply Voltage Max
12VDC
Pressure Max
0.7MPa
Operating Pressure Min
0MPa
Svhc
Bis (2-ethyl(hexyl)phthalate) (DEHP) (15-Dec-2010)
External Width
15.5mm
Fluid Temperature Max
50°C
Height
36mm
Lead Free Status / RoHS Status
na
SY100/ Application example
qValve for blow off
Vacuum Applications Possible
Can be used up to -100kPa
(Current draw: 21mA at 24V DC)
Large flow capacity style:0.75W (Current draw: 31mA at 24V DC)
Low power consumption: 0.5W
1(P)
3(R)
N.C.
2(A)
Series
Rubber Seal
Vacuum valve
3 Port Solenoid Valve
Copper free
No copper used for sections in contact with fluids.
wValve for vacuum
3(P)
1(R)
N.O.
2(A)
Atmospheric air or micro
pressure for vacuum release
Vacuum pad
Characteristics values indicated in this catalog are not guaranteed values but typical ones.
Bright colour tone and "state of the art" design
A bright grey concept has been adopted for this product
to complement the surrounding operational environment.
(Pneumatic symbols shown are typical examples.)
eOperation for single acting cylinder r Operation for air operated style fluid control valve
1(P)
3(R)
SY100
Body width: 10mm
7.85 Nl/min (Standard style)
11.78 Nl/min (Large flow capacity style)
Exceedingly long life
100 million cycles (By SMC life test data)
N.C.
2(A)
(Standard, Without light)
1(P)
3(R)
N.C.
2(A)
Air operated style
fluid control valve
2.1-1
SY
SYJ
VK
VZ
VT
VT
VP
VG
VQ
VQZ

Related parts for SY114-6LOU-Q

SY114-6LOU-Q Summary of contents

Page 1

Port Solenoid Valve Rubber Seal Series Low power consumption: 0.5W (Current draw: 21mA at 24V DC) Large flow capacity style:0.75W (Current draw: 31mA at 24V DC) Vacuum Applications Possible Can be used up to -100kPa Copper free No copper ...

Page 2

... How to Order To order a valve with lead wire length of other than 300mm, indicate part numbers of the valve without connector and the required connector ass'y separately. Example: 2000mm lead wire length For DC Lever SY114-5LO DC indicator SY100-30-4A-20 Socket DXT170-71-1 Lead wire Crimping area Core wire ...

Page 3

... Lead wire length: 2000mm SY114-5LOZ-M3-Q SY100-68-A-20 <Example 2> Lead wire length: 300mm (Standard) SY114-5LPZ-M3-Q No part numbers of connector assembly with cover are needed to be indicated in this case. SY100 Series Lead wire ( L ) — ...

Page 4

Port Direct Operated Rubber Seal Series Body ported Base mounted JIS Symbol 3 3 SY11 (A) SY12 ( (A) ( (P) (R) (P) ( P.2.1-15 M ...

Page 5

... Non-locking push style MN: Without lead wire B: Locking slotted style MO: Without connector SY100 Series Bracket P: For body ported style — : Without bracket port F: With bracket "P" piping specification only. -Q M3: With sub-plate D: Push-locking slotted style E: Push-locking lever style SY114/SY124, SY114A/SY124A only. SY SYJ VQZ 2.1-5 ...

Page 6

... B: Locking slotted style MO: Without connector connector Bracket P: For body ported style — : Without bracket F: With bracket port "P" piping specification only Piping port —: Without sub-plate M3: With sub-plate (With gasket and screw) D: Push-locking slotted style E: Push-locking lever style SY114/SY124, SY114A/SY124A only. ...

Page 7

... Construction SY114, SY114A ( (R) ( Component Parts No. Description Material q Body Resin w Cover Resin e Push rod Resin r Armature ass'y NBR/Stainless steel t Core Stainless steel y Exhaust poppet NBR u Return spring Stainless steel i Poppet spring Stainless steel o Coil ass'y — How to Order Connector Assembly SY100 30 4A ...

Page 8

SY100 Series Body Ported 1 Grommet (G), (H): SY1 3 (A)-„ „„-PM3 (- (Indicator light and surge suppressor) Manual override 1 L plug connector (L): SY1 3 (A)-„L„„-PM3 (F)-Q 2 (Indicator light and surge voltage suppressor ...

Page 9

Base Mounted (With Sub-plate Grommet (G), (H): SY1 4 (A)-„ „„-M3 plug connector (L): SY1 4 (A)-„L„„-M3-Q 2 (Indicator light and surge voltage suppressor) 15.6 P Other dimensions are same as grommet ...

Page 10

... SY1„4A Note 1) When mounted on manifold base Note 2) SY114 (A) and SY124 (A) can not be mounted on the same manifold. Note 3) Supply to R port and exhaust from P port for SY124 (A). Note 4) 30 Type is applicable only for SY113 and SY113A. Piping to exhaust port is not possible. ...

Page 11

... Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold. How to Order SS3Y1 S41 05 M3 Stations 02 2 stations 20 20 stations Note 1) SY114 (A) and SY124 (A) cannot be mounted on the same manifold. Base mounted Gasket VJ100-6-8 Applicable base Sub-plate SS3Y1-S41 type manifold base SY100 Series Applicable solenoid valve SY113-„ ...

Page 12

SY100 Series 30 Type Manifold: Top Ported/SS3Y1-30- Grommet (G), (H) 24.7 G: 300 H: 600 (Lead wire length 27.3 G„, H„ plug connector (L) 37.2 (Indicator light and surge voltage suppressor) Other dimensions are same ...

Page 13

Type Manifold: Top Ported/SS3Y1-31- Grommet (G), (H) 27 300 H: 600 (Lead wire length 30.1 G„, H„: 30.8 L plug connector (L) 40 (Indicator light and surge voltage suppressor) Other dimensions are same as grommet ...

Page 14

SY100 Series S41 Type Manifold: Side Ported/SS3Y1-S41- Grommet (G), (H) In case of M5 (Station n) A n-M5 X 0.8 (Pitch) P=10.5 (A port 300 H: 600 (Lead wire length 30.1 G„, H„: 30.8 L plug ...

Page 15

SY Series Made to Order (Contact SMC for further specifications, dimensions and delivery lead time.) Power consumption is decreased by 1/3 of standard product by reducing electrical power at holding. (This is effective when energizing time exceeds 62ms at rated ...

Page 16

2.1-16 ...

Related keywords