SY114-6LOU-Q SMC Corporation of America, SY114-6LOU-Q Datasheet - Page 2

no-image

SY114-6LOU-Q

Manufacturer Part Number
SY114-6LOU-Q
Description
VALVE, 3 PORT, CLOSED, 12DC
Manufacturer
SMC Corporation of America
Datasheet

Specifications of SY114-6LOU-Q

Supply Voltage Max
12VDC
Pressure Max
0.7MPa
Operating Pressure Min
0MPa
Svhc
Bis (2-ethyl(hexyl)phthalate) (DEHP) (15-Dec-2010)
External Width
15.5mm
Fluid Temperature Max
50°C
Height
36mm
Lead Free Status / RoHS Status
na
Operation of Manual Override
Make sure that there is no danger, since manual override
operation can make any connected equipment operate.
íNon-locking push style
íPush-locking slotted style
How to Use Plug Connector
q
b
the solenoid, making sure the lip of the lever securely
“locks” into the groove of the solenoid cover.
b
housing and pull it outward from the solenoid.
Series
2.1-2
Connection: Push the connector straight onto the pins of
Disconnecton: Press the lever against the connector
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
Connection/Disconnection of connector
Press in the direction of the arrow.
Pressing makes the valve operate. The valve can be
locked in the manual override position by turning it to the direction
that the arrow shows while keeping it pressed. If it is not turned, it
can be used as a non-locking push style.
Warning
Caution
SY100
Cover
Groove
Pin
[Standard style]
Connector
housing
[D]
Cover
Groove
Gently operate locking manual override
styles B, D using small screwdriver.
[Torque: 0.1Nm or less]
íPush-locking lever style
Pin
íLocking slotted style
Hook
Turn in the direction of arrow.
Caution
Lever
DC indicator
Socket
DXT170-71-1
Lead wire
Precautions
[B]
[E]
wCrimping connection of lead wire and socket
Strip 3.2 to 3.7mm of the lead wire ends, insert each
stripped wire into a socket and crimp contact it using
special crimping tool. Be careful that the outer insulation
of the lead wires does not interfere with the socket contact
part. Use exclusive crimping tool for crimping.
(Contact SMC for special crimping tool.)
eConnection/Disconnection of socket with lead wire
b
Insert lead wire and crimped socket into square holes
(indicated as A, B, COM) of connector. Press the socket in
fully until the hook of the socket locks into the groove of the
connector housing. Confirm the locked position by lightly
pulling on the lead wire.
b
To remove the socket from the connector, pull out lead
wire while depressing the hook of the socket with a fine
screw driver ( 1mm). If the socket is to be re-used,
reposition the hook again.
Plug Connector Lead Wire Length
Standard length is 300mm, but the following lengths are
also available.
How to Order Connector Assembly
(Only with a connector and two sockets.)
Without lead wire
Core wire contact area
Connection
Disconnection
How to Order
To order a valve with lead wire length of other than
300mm, indicate part numbers of the valve without
connector and the required connector ass'y separately.
Example: 2000mm lead wire length
For DC
SY114-5LO
SY100-30-4A-20
Socket
For DC
Socket
Hook
Hook
:
:
SY100 30 4A
SY100 30 A
Crimping area
Core wire
Insulation
Lead wire
0.2 to 0.33mm
Max. covered O.D.: ø1.7mm
Lead wire
Connector housing
Lead wire length
10
15
20
25
30
50
6
2
1000mm
1500mm
2000mm
2500mm
3000mm
5000mm
300mm
600mm