AQ0400MU24ECCFD SYNQOR, AQ0400MU24ECCFD Datasheet - Page 2

AcuQor Power Supply, Medical CF Isolation Rating

AQ0400MU24ECCFD

Manufacturer Part Number
AQ0400MU24ECCFD
Description
AcuQor Power Supply, Medical CF Isolation Rating
Manufacturer
SYNQOR
Datasheet

Specifications of AQ0400MU24ECCFD

Power Supply Type
Enclosed
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Power Rating
400W
Input Voltage
85V AC To 264V AC
Length
133.4mm
Width
88.9mm
Height
41.3mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Product # AQ0400MUxx Series
Auxillary Output
MAIN OUTPUT SPECIFICATIONS
Output power (continuous)
Nominal DC output
(Semi-regulated)
Efficiency (see figs. 3 - 10) 12 Vout, 115 Vrms, 400 W
Hold-up time (to -20%)
Maximum load capacitance 12 Vout
Output ripple voltage
Turn-on delay
Transient response
Overvoltage protection
Short circuit protection
Total regulation
Thermal protection
REMOTE_ENABLE
INPUT SPECIFICATIONS
AC input voltage
Input frequency
Input current
Power factor
Input surge current
Internal input fuses
ACuQor 400W Series ELECTRICAL CHARACTERISTICS
All specifications typical with T A = 25 °C, unless otherwise specified.
Technical Specification
(5 s transient)
voltage (at 250W)
Both AC lines
85-132/170-264 Vrms
85-132/170-264 Vrms
132-170 Vrms
12 Vout
24 Vout
36 Vout
48 Vout
48 Vout, 115 Vrms, 400 W
12 Vout, 230 Vrms, 400 W
48 Vout, 230 Vrms, 400 W
12 Vout
24 / 36 / 48 Vout
24 Vout
36 Vout
48 Vout
Switching frequency (20 MHz BW)
Twice line frequency (at 300W)
Iout steps from 50-75%
At 0.2 A/µs
Cyclic restart
Cyclic operation
Over line, load and temperature
Always on (See Note 1)
Automatic recovery
Input Low Voltage
Input High Voltage
Universal range
115 Vrms @ 400 W
230 Vrms @ 400 W
264 Vrms (cold start)
Phone 1-888-567-9596
+125 ºC (PCB Temp)
3% typ / 6% max.
100 ms recovery
115% rated Iout
16 ms @ 400 W
20 ms @ 400 W
See Figure 10
5 V @ 50 mA
0.45 V (max)
www.synqor.com
85-264 Vrms
4.15 V (min)
110-120%
40 A max.
16,000 µF
0.5% p-p
5.0% p-p
88% typ.
90% typ.
89% typ.
91% typ.
47-63 Hz
8,000 µF
4,000 µF
2,000 µF
2 s max.
±6.0%
4 Arms
2 Arms
400 W
500 W
12.4 V
37.5 V
>0.98
6.3 A
25 V
50 V
dev.
GENERAL SPECIFICATIONS
Fundamental ripple freq.
Audible noise
Weight (EA \ EC)
MTBF
ISOLATION SPECIFICATIONS
Insulation resistance
Leakage currents
ENVIRONMENTAL CHARACTERISTICS
Thermal performance
Relative humidity
Altitude
Random vibration
Shock
EMC CHARACTERISTICS
Conducted emissions
Line frequency harmonics
Voltage fluctuations
ESD air
ESD contact
Radiated immunity
Fast transients
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
SAFETY AGENCY CERTIFICATIONS
UL 60950-1:2003
CAN/CSA-C22.2 No. 60950-1:2003
EN 60950-1:2001
CE Marked
Meets NFPA 99 2005 300 µA earth leakage
NOTES:
1. Derate 1 mA per °C above 50 °C ambient temperature.
2. Leakage currents see page 4.
Isolation voltage
All certification marks appear on individual unit labels.
(SC \ RC)
(UC \ TC)
Doc.# 005-005045 Rev. B
Input
Output
Fan speed varies with temp.
MIL-217
Demonstrated
Input to output
Input to ground
Output to ground (BF & CF )
Output to ground (CFD)
Output to ground
Operating ambient (see Figure 9)
Non-operating ambient
Non-condensing
Operating
Non-operating
5-500 Hz
Half-sine, 10 ms, 3 axes
EN55011 and EN55022, FCC
part15
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
DC Output:
AC Input:
Power:
Grade:
85-264 V
12/24/36/48V
400 W Series
Medical
1224 g (43.2 oz) \ 1298 g (45.8 oz)
343 g (12.1 oz) \ 446 g (15.7 oz)
07/22/09
846 g (29.8 oz) \ 879 g (31 oz)
RMS
39 dBA @ 1 m max.
Perf Criteria A, A, B
-40 ºC to +85 ºC
70% UT 500 ms,
<5% UT 10 ms,
40% UT 100 ms
0 ºC to +70 ºC
10,000 ft max.
30,000 ft max.
343.6 kHours
Semi-reg
5000 Vpulse
TBD kHours
10 MΩ min.
See Note 2
0.03 g2/Hz
4000 Vrms
1500 Vrms
1500 Vrms
5-95% RH
20 g peak
Clause 5b
500 kHz
250 kHz
Level B
Class A
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
3 A/m
Page 2
.