EA-PS 8065-10 19" 2HE LCD EA ELEKTRO-AUTOMATIK, EA-PS 8065-10 19" 2HE LCD Datasheet

PSU, 19"

EA-PS 8065-10 19" 2HE LCD

Manufacturer Part Number
EA-PS 8065-10 19" 2HE LCD
Description
PSU, 19"
Manufacturer
EA ELEKTRO-AUTOMATIK

Specifications of EA-PS 8065-10 19" 2HE LCD

Power Supply Type
Bench
Power Supply Output Type
Variable
No. Of Output Channels
1
Input Frequency
50Hz
Output Voltage
65V
Output Current
10A
Power Rating
650W
Input Voltage
90VAC To 264VAC
Length
380mm
No. Of Outputs
1
Width
482.6mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Programmierbare Labornetzgeräte
Produktkatalog
2009
Programmable Laboratory Power Supplies
Product Catalogue

Related parts for EA-PS 8065-10 19" 2HE LCD

EA-PS 8065-10 19" 2HE LCD Summary of contents

Page 1

Programmierbare Labornetzgeräte Produktkatalog Programmable Laboratory Power Supplies Product Catalogue 2009 ...

Page 2

... Thus frequently used settings are at immediate reach to the user. making the Units as from 1kW output power are output stage which provides a hig- ...

Page 3

... Displays and controls Output voltage and current are clearly visualised on two four-digit displays. The functional status of the unit and its buttons are indicated via LEDs, providing easier and most comfortable usage to the user. Output voltage, current and OVP values can be set by two - adjustment is provided as well. With the „ ...

Page 4

... RS232, CAN, USB, GPIB (IEEE) or Ethernet (upon request). The interface slot is located on the rear panel, making it easy for the user to plug-in a new interface or to replace an existing one. For the choice of interfaces see page 45. • High speed ramping (units as from 1kW), see page 43 ...

Page 5

... The units are provided with a memory function for five different preset values, with the ability to save and recall these just by the push of a button Thus frequently used settings are at immediate reach to the user. making the work easy and time efficient. Units as from 1kW output power are ...

Page 6

... Analogue Interface The analogue interface terminal is located on the rear of the device. It offers analogue inputs to set voltage, current and power (models from 1kW) from 0...100% through control voltages from 0V...10V or 0V...5V. ...

Page 7

... EA-PS 8160-04 DT EA-PS 8080-40 DT EA-PS 8080-60 DT EA-PS 8360-10 DT EA-PS 8360-15 DT 90...264V 90...264V 90...264V 45...65Hz 45...65Hz 45...65Hz >0,99 >0,99 >0,99 0...160V 0...80V 0...80V <0,05% <0,05% <0,05% <0,02% < ...

Page 8

... Thus frequently used settings are at immediate reach to the user. making the Units as from 1kW output power are output stage which provides a higher ...

Page 9

... over- and undervoltage protection, the actual control state (CV,CC,CP), errors and settings of the setup menu are clearly displayed. In order to ease adjusting of values by the existing rotary setting mode, just by a key stroke. All these features contribute to an operator friendliness. ...

Page 10

... RS232, CAN, USB, GPIB (IEEE) or Ethernet (upon request). The interface slot is located on the rear panel, making it easy for the user to plug in a new interface or to replace an existing one. The interface will be automatically detected and installed by the device For the choice of interfaces see page 31. ...

Page 11

... General The microprocessor controlled laboratory power supplies of series EA-PSI 8000 T cover state-of-the-art technology. They already offer many functions and features in their standard version, making the use of this equipment remar- kably easy and most effective. User and process profiles can be configured, saved and archived so that the reproducibility of a test or other appli- cation is improved ...

Page 12

... Remote sense The standard sense input can be connected directly to the load in order to compensate voltage drops along the power leads. If the sense input is connected to the load, the power supply will be adjusting the output voltage au- tomatically to make ensure the accurate required voltage is available at the load. ...

Page 13

... EasyPower, which can also read out and save function sets. For each sequence, the maximum power or optional the internal resistance and a repetition from once up to 254 As well, the repetition of a whole function-run can be con stored ...

Page 14

... Ethernet (upon request) and an isolated analogue interface, all as pluggable cards. Also see page 45. • Internal resistance regulation • High speed ramping (devices as from 1kW), see page 43 EA-PSI 8016-20 T EA-PSI 8032-10 T EA-PSI 8065-05 T EA-PSI 8032-20 T EA-PSI 8065-10 T 90...264V 90...264V 90...264V 45...65Hz 45 ...

Page 15

... Carrying handle General The microprocessor controlled laboratory power supplies of series EA-PSI 8000 DT cover state-of-the-art techno- logy. They already offer many functions and features in their standard version, making the use of this equipment remarkably easy and most effective. - archived so that the reproducibility of a test or other appli- cation is improved ...

Page 16

... Remote sense The standard sense input can be connected directly to the load in order to compensate voltage drops along the power leads. If the sense input is connected to the load, the power supply will be adjusting the output voltage au- tomatically to make ensure the accurate required voltage is available at the load. ...

Page 17

... EasyPower, which can also read out and save function sets. For each sequence, the maximum power or optional the internal resistance and a repetition from once up to 254 As well, the repetition of a whole function-run can be con stored ...

Page 18

... Ethernet (upon request) and an isolated analogue interface, all as pluggable cards. Also see page 45 • Internal resistance regulation • High speed ramping (devices from 1kW), see page 43 EA-PSI 8016-20 DT EA-PSI 8032-10 DT EA-PSI 8065-05 DT EA-PSI 8032-20 DT EA-PSI 8065-10 DT 90...264V 90...264V 90...264V 45...65Hz 45 ...

Page 19

... Carrying handle General The microprocessor controlled laboratory power supplies of series EA-PSI 8000 2U cover state-of-the-art techno- logy. They already offer multiple functions and features in their standard version, making the use of this equipment remarkably easy and most effective. - archived so that the reproducibility of a test or other appli- cation is improved ...

Page 20

... Remote sense The standard sense input can be connected directly to the load in order to compensate voltage drops along the power leads. If the sense input is connected to the load, the power supply will be adjusting the output voltage au- tomatically to make ensure the accurate required voltage is available at the load. ...

Page 21

... Function manager Function-runs for sequences can be controlled via the control panel using the control and monitoring software EasyPower, via the communication interfaces, controlled as well, and can be read out, processed and documented also function-run. For each sequence, the maximum power or optional the ...

Page 22

... Ethernet (upon request) and an isolated analogue interface, all as pluggable cards. Also see page 31. • Internal resistance regulation • High speed ramping (devices from 1kW) • Two-quadrants module EA-PSI 8032-20 2U EA-PSI 8065-10 2U EA-PSI 8160-04 2U EA-PSI 8080-40 2U EA-PSI 8080-60 2U 90...264V 90...264V 90...264V 45...65Hz 45...65Hz 45...65Hz > ...

Page 23

... EA-PSI 9000 is designed to state-of-the-art tech- nology. The user-friendly and interactive menu guidance offers a lot of functions and features as standard, making the use of the device much easier and more effective. User profiles and function sequences can be simply confi- gured, saved and stored for a better reproducibility of tests and other applications ...

Page 24

... The all time good readable graphic display shows a clear representation of set values, actual output values, the operation state and the actual function of the operation press buttons. ...

Page 25

... Also four parameter blocks for can be deposited in a preset list. From this list parameter blocks can be loaded for frequently required values. A special preset mode is designed to call the deposited parameter blocks directly. This function is useful, for ex- ample to realise rapid output voltage changes. ...

Page 26

... RS232, CAN, USB, GPIB (IEEE), Ethernet (upon request analogue interface interface. The interface slot is accessible on the rear panel, making it possible to easily place a new interface or replace an used automatically. For interfaces see page 31. • Internal resistance regulation • Two-quadrants module (also see page 42) • ...

Page 27

... EA-PSI 9000 1500W - 9000W PROGRAMMIERBARE LABORNETZGERÄTE / PROGRAMMABLE LABORATORY POWER SUPPLIES Technische Daten Technical Data Eingangsspannung Input voltage -Derating 90...180V -Derating 90...180V -Derating 180...207V L-N -Derating 180...207V L-N -Frequenz -Frequency -Leistungsfaktorkorrektur -Power factor correction -Netzsicherung -Mains fuse Ausgangsspannung Output voltage -Stabilitä ...

Page 28

... The power output is available via safety sockets on the front face. In order to operate the unit via a PC the relevant adaptor is required; adaptors for RS232, USB and IEEE are available, and are connected to the interface at the rear of the unit. A conversion kit for 19“ is available as an option. PSI 6018-05 PSI 6018-10 ...

Page 29

... Options: Digital interfaces RS232, CAN, USB General The state-of-the-art microprocessor controlled chassis mounting power-supplies from series EA-PSI 800 R have a multitude of functions and features making the use of this Equipment easier and more effective. Units as from 1kW output power are output stage which provides a higher ...

Page 30

... Sense input The sense input can be connected directly to the load to compensate voltage drops along the power leads. If the sense input is connected to the load, the power supply will correct the output voltage to ensure that the accurate required voltage is available on the load. ...

Page 31

... Die EA-Schnittstellenkarten sind digitale bzw. analoge Steckkarten für verschiedene Serien von programmierba- ren Netzgeräten, Batterieladern und elektronischen Lasten. Je nach Modell sind 1 oder 2 Steckplätze verfügbar. Modelle EA-IF-U2, -C2, -R2 sind für PSI 800 und BCI 800. USB EA-IF-U1 Art.Nr. 33100212 EA-IF-U2 Art ...

Page 32

... EA-Elektro-Automatik GmbH & Co. KG Entwicklung - Produktion - Vertrieb Development - Production - Sales Helmholtzstraße 31-33 41747 Viersen Deutschland / Germany Telefon: +49 (0) 2162 / 37 85-0 Telefax: +49 (0) 2162 / 16 230 ea1974@elektroautomatik.de www.elektroautomatik.de EA-Elektro-Automatik Vertriebsbüro Nord/Ost Telefon: 033205 - 227997 Telefax: 033205 - 227998 ea-ost@elektroautomatik.de EA-Elektro-Automatik Vertriebsbüro Süd ...