60212 SQUARE D, 60212 Datasheet - Page 110

CIRCUIT BREAKER, THERMAL MAG, 1P, 15A

60212

Manufacturer Part Number
60212
Description
CIRCUIT BREAKER, THERMAL MAG, 1P, 15A
Manufacturer
SQUARE D
Series
C60Nr
Datasheet

Specifications of 60212

Actuator Style
Toggle
No. Of Poles
1
Current Rating
15A
Voltage Rating Vdc
60V
Voltage Rating Vac
120V
Mounting Type
DIN Rail
Tripping Characteristic
C
Voltage Ac
120V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
UL Listed Masterpact
Control Units
STR 18M
110
STR 28D
STR 38S
STR 58U
Control Unit (instantaneous protection only)
STR18M
Control Unit (long-time and instantaneous protection)
STR28D (long-time = 0.4x1 sensor rating)
STR28DP (long-time = 0.8x1 plug rating)
Options
Ammeter
Pre-trip overload indication switch
Control Unit (long-time, short-time and instantaneous protection)
STR38S (long-time = 0.4x1 sensor rating)
STR38SP (long-time = 0.8x1 plug rating)
Ground-fault Protection ➀
Residual type
Source ground return type
External neutral sensor (TCE) – see page
Options
Ammeter
Pre-trip overload indication switch
LED fault indicators on the circuit breaker front face
(PIL or AD module or 24 Vdc external power supply is required)
Power supply with battery
Control Unit (long-time, short-time and instantaneous protection)
STR58U (long-time = 0.4x1 sensor rating)
STR58UP (long-time = 0.8x1 plug rating)
Ground-fault Protection ➀➁
Residual type
Source ground return type
External neutral sensor (TCE) – see page
Options
Ammeter
Pre-trip overload indication switch
LED fault indicators on the circuit breaker front face
(PIL or AD module or 24 Vdc external power supply is required)
Segregated alarm switch (fault indicator [F] included. Output contact as a function of selected fault type.
24 Vdc external power supply or AD module is mandatory)
Power supply with battery
Zone-selective interlocking, for short-time protection (ST) and ground-fault protection (T/W)
Load monitoring (outputs optical trial output contacts 0.1 A/240 Vac)
Communication (transmits all the trip unit parameters via Digipact
➀ External neutral sensor not included.
➁ External AD module (see page 112) is required if load is below 20% or if setting is red zone.
➂ Communication options are available for Masterpact circuit breakers with STR 58U control unit,
®
C option and Digipact communcation modules. See page 112.
Circuit Breakers
DE2F
112
112
Discount
Schedule
®
modules) ➂
I
ALR
T
W
I
ALR
F
PIL
T
W
I
ALR
F
FV
PIL
R
C
Z
Option
Continued on next page
List Price
$ 1406
No charge
No charge
No charge
1489
1380
1718
2069
2446
2337
1057
896
879
980
896
357
240
879
980
896
357
978
240
815
641