E3MC-A41 Omron, E3MC-A41 Datasheet - Page 10

RGB BUILT-IN AMP, PNP OUTPT TY

E3MC-A41

Manufacturer Part Number
E3MC-A41
Description
RGB BUILT-IN AMP, PNP OUTPT TY
Manufacturer
Omron
Series
-r
Datasheet

Specifications of E3MC-A41

Sensing Distance
60mm
Number Of Outputs
1
Output Type
PNP
Voltage - Supply
12 V ~ 24 V
Current - Supply
100mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E3MC
1-output Models (E3MC-A@@/E3MC-X@@/E3MC-Y@@)
1. Bank Selection
Set the Mode Selector to the TEACH mode and then select the
BANK using the SELECT button.
2. Color Registration
3. Threshold Adjustment (If Required)
Press the SELECT button in ADJ mode with or without the sens-
ing object located at the detection point. The bank selected in the
TEACH mode or RUN mode will become the bank for the ADJ
mode.
4. Operation
The detection operation is performed in RUN mode. The regis-
tered color is selected with bank selection input.
10
Settings
Locate the registered object at the detection
point and press the TEACH button.
Sensing object
Sensor
Registered object
Sensor
No Good
OK
All the red threshold indicators
will flash if registration has not
been completed.
Refer to Technical Guide on
page 12.
Detection Level and Tolerance
As the detected color becomes closer to the registered color, the
number of lit detection level indicators increase. The control out-
put of the E3MC will be ON if the detection level exceeds the
threshold level and OFF if the detection level does not exceed the
threshold level provided that the E3MC is in conformity output
mode.
Set the threshold to a higher level for highly-precise color discrim-
ination and to a lower level to ignore minor tint differences or dirt
retention.
Operation
indicator: ON
Control output:
ON
Detection level
Threshold
value
Tolerance
All the detection level
indicators are ON.
The threshold is set to 4.
Operation
indicator: OFF
Control output:
OFF
Detection level
E3MC
Threshold
value

Related parts for E3MC-A41