LQ104V1DG61 Sharp Microelectronics, LQ104V1DG61 Datasheet - Page 16

TFT Displays & Accessories 10.4 VGA STG 2

LQ104V1DG61

Manufacturer Part Number
LQ104V1DG61
Description
TFT Displays & Accessories 10.4 VGA STG 2
Manufacturer
Sharp Microelectronics
Datasheet

Specifications of LQ104V1DG61

Diagonal
10.4 in
Viewing Area (w X H)
211.2 mm x 158.4 mm
Pixel Density
640 x 480
Module Size (w X H X T)
246.5 mm x 179.4 mm x 13.7 mm
Backlighting
White
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LQ104V1DG61
Manufacturer:
HITACHI
Quantity:
1 000
Part Number:
LQ104V1DG61
Quantity:
11
12.Handling Precautions
l) Connect GND to 4 place of mounting holes to stabilize against EMI and external noise.
m) There are high voltage portions on the backlight and very dangerous. Careless touch may lead to
a) Be sure to turn off the power supply when inserting or disconnecting the cable.
b) Be sure to design the cabinet so that the module can be installed without any extra stress such as
c) Since the front polarizer is easily damaged, pay attention not to scratch it.
d) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
e) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
f) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface.
g) Since CMOS LSI is used in this module, take care of static electricity and injure the human earth
h) Since there is a circuit board in the module back, stress is not added at the time of a design assembly.
i) Protection film is attached to the module surface to prevent it from being scratched .
j) The polarizer surface on the panel is treated with Anti-Glare for low reflection. In case of attaching
k) Do not expose the LCD panel to direct sunlight. Lightproof shade etc. should be attached when LCD
n) When handling LCD modules and assembling them into cabinets, please be noted that long-term
o) Cold cathode fluorescent lamp in LCD panel contains a small amount of mercury, please follow local
p) Be careful of a back light lead not to pull by force at the time of the wiring to an inverter, or line processing.
q) When install LCD modules in the cabinet, recommended torque value is “0.294 0.02N m (3.0 0.2kgf cm)”.
r) Liquid crystal contained in the panel may leak if the LCD is broken. Rinse it as soon as possible if it gets inside your eye
s) Notice:Never dismantle the module , because it will cause failure.
t) Be careful when using it for long time with fixed pattern display as it may cause afterimage.
u) Adjusting volume have been set optimally before shipment, so do not change any adjusted value.
v) If a minute particle enters in the module and adheres to an optical material, it may cause display non-uniformity issue,
electrical shock. When exchange lamps or service, turn off the power without tail.
Be sure to confirm it in the same condition as it is installed in your instrument.
Blow away dust on the polarizer with antistatic N
It is recommended to peel off softly using the adhesive tape when soil or finger oil is stuck to the polarizer.
When unavoidable, wipe off carefully with a cloth for wiping lenses.
warp or twist.
Handle with care.
Please make it like. If stress is added, there is a possibility that circuit parts may be damaged.
Peel the film off slowly , just before the use, with strict attention to electrostatic charges.
Blow off 'dust' on the polarizer by using an ionized nitrogen.
protective board over the LCD, be careful about the optical interface fringe etc. which degrades
display quality.
panel is used under such environment.
storage in the environment of oxidization or deoxidization gas and the use of such materials as
reagent,solvent, adhesive, resin, etc. which generate these gasses, may cause corrosion and
discoloration of the LCD modules.
ordinances or regulations for disposal.
or mouth by mistake.
If adjusted value is changed, the specification may not be satisfied.
etc. Therefore, fine-pitch filters have to be installed to cooling and inhalation hole if you intend to install a fan.
when handling.Observe all other precautionary requirements in handling components.
2
blow. It is undesirable to wipe off because a polarizer is sensitive.

Related parts for LQ104V1DG61