AD7707BR Analog Devices Inc, AD7707BR Datasheet - Page 38

no-image

AD7707BR

Manufacturer Part Number
AD7707BR
Description
A/D Converter (A-D) IC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7707BR

Peak Reflow Compatible (260 C)
No
No. Of Bits
16 Bit
Leaded Process Compatible
No
Mounting Type
Surface Mount
Features
3V/5V, 1mW, 2?Channel, 16?Bit
Package / Case
20-SOIC
Rohs Status
RoHS non-compliant
Number Of Bits
16
Sampling Rate (per Second)
500
Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
1mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7707BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7707BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7707BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7707BRZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7707
WRITE TO COMMUNICATIONS REGISTER SELECTING
CHANNEL AND SETTING UP NEXT OPERATION TO BE A
WRITE TO THE CLOCK REGISTER (20 HEX)
WRITE TO CLOCK REGISTER SETTING THE CLOCK
BITS IN ACCORDANCE WITH THE APPLIED MASTER
CLOCK SIGNAL AND SELECT UPDATE RATE FOR
SELECTED CHANNEL (0C HEX)
WRITE TO COMMUNICATIONS REGISTER SELECTING
CHANNEL AND SETTING UP NEXT OPERATION TO BE A
WRITE TO THE SETUP REGISTER (10 HEX)
WRITE TO COMMUNICATIONS REGISTER SETTING UP
NEXT OPERATION TO BE A READ FROM THE DATA
REGISTER (38 HEX)
CONFIGURE AND INITIALIZE MICROCONVERTER/
MICROPROCESSOR SERIAL PORT
WRITE TO SETUP REGISTER CLEARING F SYNC,
SETTING UP GAIN, OPERATING CONDITIONS AND
INITIATING A SELF-CALIBRATION ON SELECTED
CHANNEL (40 HEX)
POWER-ON/RESET FOR AD7707
READ FROM DATA REGISTER
NO
POLL DRDY PIN
START
DRDY
LOW?
YES
Figure 22. Flowchart for Setting Up and Reading from the AD7707
Rev. B | Page 38 of 52
WRITE TO COMMUNICATIONS REGISTER SETTING UP NEXT
OPERATION TO BE A READ FROM THE COMMUNICATIONS
REGISTER (08 HEX)
WRITE TO COMMUNICATIONS REGISTER SETTING UP
NEXT OPERATION TO BE A READ FROM THE DATA
REGISTER (38 HEX)
POLL DRDY BIT OF COMMUNICATIONS REGISTER
READ FROM COMMUNICATIONS REGISTER
READ FROM DATA REGISTER
NO
DRDY
LOW?
YES