53210A-400 AGILENT TECHNOLOGIES, 53210A-400 Datasheet - Page 7

Frequency Counter With GPIB Port, 10, 0.2 Ppm

53210A-400

Manufacturer Part Number
53210A-400
Description
Frequency Counter With GPIB Port, 10, 0.2 Ppm
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 53210A-400

Bandwidth
350MHz
Counter Measuring Functions
Frequency, Period,Totalize, Ratio, Time Interval, Rise/Fall, Width, Burst Width, Duty Cycle, Phase, PRI, PRF
Lead Free Status / RoHS Status
na
1. Maximum display resolution for frequency and period. Totalize display resolution is 15 digits, time interval based measurements
2. Continuous, gap-free measurements limits the gate time setting to 10 µs to 1000 s in 10 µs steps.
3. Refer to the gate characteristics section for more details on advanced gate capabilities.
4. Measurements on each input channel are performed simultaneously using one gate interval. The actual measurement gate interval
5. Maximum sample rate. Actual sample rate will be limited by the input signal edge rate for signals slower than the selected sample
6. Assumes two frequencies are identical, only shifted in phase.
7. Manual control of gate width and gate delay are allowed only for wide pulsed mode.
8. For pulsed signals > -7 dBm (100 mVrms) while gated on.
9. For totalize, time interval and frequency measurements, you may get measurement readings beyond the
10. Applies when burst width * Carrier Freq >80.
11. Specifications apply if measurement channels are in 5 V range, DC coupled, 50 Ω terminated and at fixed level for: time interval
12. Option 150 microwave pulse/burst measurement descriptions:
13. For option 115, use -10 dBm (71 mVrms) for lower sensitivity limit.
Measurement Characteristics
Pulse/burst frequency and pulse envelope detector (Option 150)
Pulse/burst measurements
Pulse/burst width
for carrier frequency
measurements
Minimum pulse/burst
width for envelope
measurements
Acquisition
PRF, PRI range
Pulse detector response
time (typ)
Pulse width accuracy
Power ratio (typ)
Power ranged and
sensitivity (sinusoidal)
typ)
are 12 digits.
on each channel will be synchrounous with edges of each input signal.
rate. Maximum timestamp rate offers minimal FM tolerance. If high FM tolerance is required, use lower timestamp rates.
range stated, but the accuracy of those readings is not specified.
single and dual channel, pulse width, duty, phase, single period and rise/fall time measurements.
amplitude
- 6 dB
13
p-p
8
+ width burst (on)
10
-6 dB Detector Level
PRI = 1/PRF
Burst carrier frequency
PRF
- width burst (off)
53210A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
continued
-12 dB Detector Level
+ width burst (on)
(Option 106 only)
7
PRI = 1/PRF
PRF
12
Burst carrier frequency
53220A
- width burst (off)
- 12 dB
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
interval (PRI), pulse repeti-
tion frequency (PRF), posi-
20 ns + (2*carrier period)
Carrier frequency, carrier
tive and negative width
period, pulse repetition
+13 dBm (1 Vrms) to
-13 dBm (50 mVrms)
Narrow: <17 µs
Auto, Manual
1 Hz – 10 MHz
15 ns rise, fall
Wide: >13 µs
>200 ns
53230A
>15 dB
>50 ns
7