821054PQF Integrated Device Technology (Idt), 821054PQF Datasheet - Page 19

no-image

821054PQF

Manufacturer Part Number
821054PQF
Description
Audio Codec 4ADC / 4DAC 64-Pin PQFP
Manufacturer
Integrated Device Technology (Idt)
Type
PCMr
Datasheet

Specifications of 821054PQF

Package
64PQFP
Number Of Channels
4ADC /4 DAC
Number Of Dacs
4
Operating Supply Voltage
5 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
821054PQFG
Manufacturer:
IDT
Quantity:
20 000
IDT821054 QUAD PROGRAMMABLE PCM CODEC WITH MPI INTERFACE
Note 1: In block 3 of the Coe-RAM, word 5 to word 8 are used for tone coefficients while word 1 to word 4 are used for GIS coefficients. If users do not want to change the GIS coefficient
while writing tone coefficients to the Coe-RAM, they can stop the procedure of consecutive adjacent addressing (after writing data to word 5) by pulling the CS signal to high, or they can
rewrite word 1 to word 4 with the original GIS coefficients.
3.1.6.4
data byte 9
data byte 10
data byte 11
data byte 12
data byte 13
data byte 14
data byte 15
data byte 16
• Reading from the Coe-RAM
1010,0011
0001,0010
0110,0010
After the preceding commands are executed, data will be sent out as follows:
1000,0001
data byte 1
data byte 2
data byte 3
data byte 4
data byte 5
data byte 6
data byte 7
data byte 8
data byte 9
data byte 10
data byte 11
data byte 12
data byte 13
data byte 14
data byte 15
data byte 16
• Writing to the FSK-RAM:
1111,0010
data byte 1
data byte 2
data byte 3
data byte 4
data byte 5
data byte 6
data byte 7
data byte 8
data byte 9
data byte 10
data byte 11
data byte 12
data byte 13
data byte 14
data byte 15
data byte 16
• Reading from the FSK-RAM:
0111,0010
After the preceding commands are executed, data will be sent out as follows:
1000,0001
Example of Programming the FSK-RAM
high byte of word 4 of block 3 (see Note 1)
low byte of word 4 of block 3
high byte of word 3 of block 3
low byte of word 3 of block 3
high byte of word 2 of block 3
low byte of word 2 of block 3
high byte of word 1 of block 3
low byte of word 1 of block 3
Channel Enable command
Data for GREG6 (Channel 1 is enabled for programming)
Coe-RAM read command (The address of '00010' is located in block 3, which means that block 3 will be read.)
Identification code
data read out from high byte of word 8 of block 3
data read out from low byte of word 8 of block 3
data read out from high byte of word 7 of block 3
data read out from low byte of word 7 of block 3
data read out from high byte of word 6 of block 3
data read out from low byte of word 6 of block 3
data read out from high byte of word 5 of block 3
data read out from low byte of word 5 of block 3
data read out from high byte of word 4 of block 3
data read out from low byte of word 4 of block 3
data read out from high byte of word 3 of block 3
data read out from low byte of word 3 of block 3
data read out from high byte of word 2 of block 3
data read out from low byte of word 2 of block 3
data read out from high byte of word 1 of block 3
data read out from low byte of word 1 of block 3
FSK-RAM write command (The address of '010' is located in block 3, which means that data will be written to block 3.)
high byte of word 8 of block 3
low byte of word 8 of block 3
high byte of word 7 of block 3
low byte of word 7 of block 3
high byte of word 6 of block 3
low byte of word 6 of block 3
high byte of word 5 of block 3
low byte of word 5 of block 3
high byte of word 4 of block 3
low byte of word 4 of block 3
high byte of word 3 of block 3
low byte of word 3 of block 3
high byte of word 2 of block 3
low byte of word 2 of block 3
high byte of word 1 of block 3
low byte of word 1 of block 3
FSK-RAM read command (The address of '010' is located in block 3, which means that block 3 will be read.)
Identification code
19
INDUSTRIAL TEMPERATURE RANGE

Related parts for 821054PQF