M48T201V-85MH1TR STMicroelectronics, M48T201V-85MH1TR Datasheet - Page 19

no-image

M48T201V-85MH1TR

Manufacturer Part Number
M48T201V-85MH1TR
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of M48T201V-85MH1TR

Bus Type
Parallel
User Ram
512KB
Operating Supply Voltage (typ)
3.3V
Package Type
SOH
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Operating Temperature Classification
Commercial
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Pin Count
44
Mounting
Surface Mount
Date Format
DW:DM:M:Y
Time Format
HH:MM:SS
Lead Free Status / RoHS Status
Not Compliant
M48T201Y, M48T201V
3.5
Note:
Setting the alarm clock
Registers 7FFF6h-7FFF2h contain the alarm settings. The alarm can be configured to go off
at a prescribed time on a specific month, day of month, hour, minute, or second or repeat
every month, day of month, hour, minute, or second.
It can also be programmed to go off while the M48T201Y/V is in the battery backup to serve
as a system wake-up call.
Bits RPT5-RPT1 put the alarm in the repeat mode of operation.
configurations. Codes not listed in the table default to the once per second mode to quickly
alert the user of an incorrect alarm setting.
User must transition address (or toggle chip enable) to see flag bit change.
When the clock information matches the alarm clock settings based on the match criteria
defined by RPT5-RPT1, the AF (alarm flag) is set. If AFE (alarm flag enable) is also set, the
alarm condition activates the IRQ/FT pin. To disable alarm, write ’0’ to the alarm-date
register and RPT1-5. The IRQ/FT output is cleared by a READ to the flags register as
shown in
value of the alarm flag has been reset to '0.'
The IRQ/FT pin can also be activated in the battery backup mode. The IRQ/FT will go low if
an alarm occurs and both ABE (alarm in battery backup mode enable) and AFE are set. The
ABE and AFE bits are reset during power-up, therefore an alarm generated during power-up
will only set AF. The user can read the flag register at system boot-up to determine if an
alarm was generated while the M48T201Y/V was in the deselect mode during power-up.
Figure 8 on page 20
Figure 7.
Table 6.
RPT5
1
1
1
1
1
0
A0-A18
ACTIVE FLAG BIT
IRQ/FT
Figure
Alarm interrupt reset waveforms
Alarm repeat modes
RPT4
1
1
1
1
0
0
7. A subsequent READ of the flags register is necessary to see that the
illustrates the backup mode alarm timing.
RPT3
1
1
1
0
0
0
RPT2
1
1
0
0
0
0
ADDRESS 7FFF0h
15ns Min
RPT1
1
0
0
0
0
0
Table 6
Once per second
Once per minute
Once per month
Alarm setting
Once per hour
Once per year
Once per day
HIGH-Z
shows the possible
Clock operation
AI02331
19/37