SLFDM44H-512MM1UI STEC, SLFDM44H-512MM1UI Datasheet - Page 21

no-image

SLFDM44H-512MM1UI

Manufacturer Part Number
SLFDM44H-512MM1UI
Description
Manufacturer
STEC
Type
Flash Diskr
Datasheet

Specifications of SLFDM44H-512MM1UI

Density
512MByte
Operating Supply Voltage (typ)
3.3/5V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Package Type
Not Required
Mounting
Plug in
Pin Count
44
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
3.18/4.75V
Operating Supply Voltage (max)
3.465/5.25V
Programmable
Yes
Lead Free Status / RoHS Status
Compliant
SLFDM(40/44)(V/H)-xxx(M/G)M1U(I)
Datasheet
6.0 Supported ATA Commands
The ATA commands used by the IDE Flash Disk Module are listed in Table 20. Refer to ATA/IDE
standards for details.
Check Power Mode
Execute Drive Diagnostic
Erase Sector(s)
Format Track
Identify Drive
Idle
Idle Immediate
Initialize Drive Parameters
NOP
Read Buffer
Read DMA
Read Multiple
Read Long Sector
Read Sector(s)
Read Verify Sector(s)
Recalibrate
Request Sense
(Extended Error)
Seek
Command Set
Table 20: IDE Flash Disk Module Supported ATA Commands
E5h or 98h
90h
C0h
50h
ECh
E3h or 97h
E1h or 95h
91h
00h
E4h
C8h
C4h
22h or 23h
20h (w/ retry)
21h (w/o retry)
40h (w/ retry)
1Xh
03h
7Xh
41h (w/o retry
Code
61000-04498-112, April 2008
This command checks the power mode.
Command performs the internal diagnostic tests implemented
by the Disk Module. Diagnostic Code is returned in Error
Register.
Command is used to pre-erase/condition data sectors in advance.
Command writes the desired head/cylinder of the selected drive
with a vender unique data pattern (typically 00h or FFh). This
Disk Module accepts a sector buffer of data from the host to
follow the command with the same protocol as the Write Sector
Command although the information in the buffer is not used.
Command lets the host receive parameter information from the
Disk Module in the same protocol as Read Sector(s) command.
Command causes the Disk Module to set BSY, enter the Idle
mode, clear BSY, and generate an interrupt. If sector count is
non-zero, automatic power down mode is enabled. If sector
count is zero, the automatic power down mode is disabled.
This command causes the IDE Flash Disk Module to set BSY,
enter the Idle mode, clear BSY, and generate an interrupt.
This command enables the host to set the number of sectors
per track and the number of heads per cylinder.
No Operation.
This command enables the host to read the current contents of
the IDE Flash Disk Module’s sector buffer.
Command is sector read command used for MWDMA transfer.
Command performs similarly to the Read Sectors command.
Interrupts are not generated on each sector, but on transfer of a
block which contains the number of sectors defined by a Set
Multiple command.
Command performs similarly to the Read Sector(s) command
except that it returns 516 bytes of data instead of 512 bytes.
Command reads from 1 to 256 sectors as specified in the Sector
Count register. Sector count of 0 requests 256 sectors. Transfer
begins at the sector specified in the Sector Number register.
This command verifies one or more sectors on the Disk Module
by transferring data from the flash media to the data buffer in the
Disk Module and verifying that the ECC is correct. This
command is identical to the Read Sectors command, except
that DRQ is never set and no data is transferred to the host.
The Disk Module performs only the interface timing and register
operations. When this command is issued, the Disk Module sets
BSY and waits for an appropriate length of time, after which it
clears BSY and issues an interrupt. When this command ends
normally, the Disk Module is initialized.
Command requests extended error code after command ends
with error. Extended error code is returned in the Error Register
This command is effectively a NOP command to the Disk
Module although it does perform a range check.
Description
IDE Flash Disk Module
21