AT88SC0808CA-TU Atmel, AT88SC0808CA-TU Datasheet

AT88SC0808CA-TU

Manufacturer Part Number
AT88SC0808CA-TU
Description
Manufacturer
Atmel
Datasheet

Specifications of AT88SC0808CA-TU

Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Mounting
Surface Mount
Pin Count
8
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Compliant
1. Features
Table 1-1.
Pad
VCC
GND
SCL/CLK
SDA/IO
RST
One of a Family of Devices with User Memories from 1-Kbit to 8-Kbits
8-Kbit (1-Kbyte) EEPROM User Memory
2-Kbit Configuration Zone
High Security Features
Smart Card Features
Embedded Application Features
High Reliability
– Eight 1-Kbit (128-byte) Zones
– Self-timed Write Cycle
– Single Byte or 16-byte Page Write Mode
– Programmable Access Rights for Each Zone
– 37-byte OTP Area for User-defined Codes
– 160-byte Area for User-defined Keys and Passwords
– 64-bit Mutual Authentication Protocol (Under License of ELVA)
– Cryptographic Message Authentication Codes (MAC)
– Stream Encryption
– Four Key Sets for Authentication and Encryption
– Eight Sets of Two 24-bit Passwords
– Anti-Tearing Function
– Voltage and Frequency Monitors
– ISO 7816 Class B (3V) Operation
– ISO 7816-3 Asynchronous T=0 Protocol (Gemplus® Patent)
– Multiple Zones, Key Sets and Passwords for Multi-application Use
– Synchronous 2-wire Serial Interface for Faster Device Initialization
– Programmable 8-byte Answer-To-Reset Register
– ISO 7816-2 Compliant Modules
– Low Voltage Operation: 2.7V – 3.6V
– Secure Nonvolatile Storage for Sensitive System or User Information
– 2-wire Serial Interface
– 1.0 MHz Compatibility for Fast Operation
– Standard 8-lead Plastic Packages
– Same Pin Configuration as AT24CXXX Serial EEPROM in SOIC and PDIP Packages
– Endurance: 100,000 Cycles
– Data Retention: 10 years
– ESD Protection: 2,000V min
Pads
Description
Supply Voltage
Ground
Serial Clock Input
Serial Data Input/Output
Reset Input
ISO Module
C1
C5
C3
C7
C2
“SOIC, PDIP”
NC
8
4
6
5
TSSOP
NC
8
1
6
3
CryptoMemory
AT88SC0808CA
Preliminary
Summary
5204AS–CRYPT–6/08

Related parts for AT88SC0808CA-TU

AT88SC0808CA-TU Summary of contents

Page 1

... Data Retention: 10 years – ESD Protection: 2,000V min Table 1-1. Pads Pad Description VCC Supply Voltage GND Ground SCL/CLK Serial Clock Input SDA/IO Serial Data Input/Output RST Reset Input ISO Module “SOIC, PDIP” CryptoMemory AT88SC0808CA Preliminary Summary TSSOP 5204AS–CRYPT–6/08 ...

Page 2

... Up to four unique key sets may be used for these operations. The AT88SC0808CA offers the ability to communicate with virtually any smart card reader using the asynchronous protocol (Gem- plus Patent) defined in ISO 7816-3 ...

Page 3

... Upon activation of the reset sequence, the device outputs bytes contained in the 64- bit Answer-To-Reset register. An internal pull-up on the RST input pad allows the device to oper- ate in synchronous mode without bonding RST. The AT88SC0808CA does not support an Answer-To-Reset sequence in the synchronous mode of operation. ...

Page 4

... RST Input High Current IH V SDA/IO Output High Voltage OH V SDA/IO Output Low Voltage OL I SDA/IO Output High Current OH I SDA/IO Output Low Current OL AT88SC0808CA [Preliminary] 4 ⋅ +150⋅ +2.7 to 3.6V -40⋅C to +85⋅C (unless otherwise noted Test Condition Min 2.7 Async WRITE at 3.57MHz ...

Page 5

... Data In Hold Time SU.DAT t Data In Set-up Time SU.STO t Stop Set-up Time DH t Data Out Hold Time WR t Write Cycle Time WR 5204AS–CRYPT–6/08 AT88SC0808CA [Preliminary] = +2.7 to 3.6V -40°C to +85° 30pF (unless otherwise noted Min 200 200 10 100 200 20 Max Units ...

Page 6

... Polling" to properly recover from the condition. Acknowledge polling consists of sending a start condition followed by a valid CryptoMemory command byte and determining if the device responded with an ACKNOWLEDGE. Figure 7-1. Bus Time for 2-Wire Serial Communications. SCL: Serial Clock, SDA: Serial Data I/O AT88SC0808CA [Preliminary] 6 Figure 7-3 on page Figure 7-4 on page 7). ...

Page 7

... Figure 7-2. SCL SDA Note: Figure 7-3. Figure 7-4. 5204AS–CRYPT–6/08 AT88SC0808CA [Preliminary] Write Cycle Timing. SCL: Serial Clock, SDA: Serial Data I/O ACK 8th BIT WORDn STOP CONDITION The Write Cycle time twr is the time from a valid stop condition of a write sequence to the end of the internal clear/write cycle ...

Page 8

... If the same security requirements are selected for multiple zones, then these zones may effectively be accessed as one larger zone. Figure 8-1. User Zone ZONE $0 $00 - User 0 - $78 User 1 $ User 6 $78 $00 - User 7 - $78 AT88SC0808CA [Preliminary] 8 Output Acknowledge $ 128 Bytes 128 Bytes $ 5204AS–CRYPT–6/08 $7 ...

Page 9

... The configuration memory consists of 2048 bits of EEPROM memory used for storage of pass- words, keys, codes, and also used for definition of security access rights for the user zones. Access rights to the configuration memory are defined in the control logic and are not alterable by the user after completion of personalization 5204AS–CRYPT–6/08 AT88SC0808CA [Preliminary] 9 ...

Page 10

... PAC $B8 PAC $C0 PAC $C8 PAC $D0 PAC $D8 PAC $E0 PAC $E8 PAC $F0 $F8 AT88SC0808CA [Preliminary Answer To Reset MTZ Card Manufacturer Code Lot History Code Identification Number Nc AR1 PR1 AR2 PR2 AR5 PR5 AR6 PR6 Reserved Issuer Code For Authentication and Encryption use ...

Page 11

... Non-volatile buffering of the data is done automatically by the device. During power-up in applications using Anti-Tearing, the host is required to perform ACK polling in the event that the device needs to carry out the data recovery process. 5204AS–CRYPT–6/08 AT88SC0808CA [Preliminary] (1) User Data Clear Clear ...

Page 12

... Authentication success is memorized and active as long as the chip is powered, unless a new authentication is initialized or RST becomes active. If the new authentication request is not vali- dated, the card loses its previous authentication which must be presented again to gain access. Only the latest request is memorized. AT88SC0808CA [Preliminary ...

Page 13

... Cryptographic Message Authentication Codes AT88SC0808CA implements a data validity check function in the standard, authentication or encryption modes of operation. In the standard mode, data validity check is done through a Modification Detection Code (MDC), in which the host may read an MDC from the device in order to verify that the data sent was received correctly ...

Page 14

... Program Only For a user zones protected by this feature, data can only be programmed (bits change from a “1” “0”), but not erased (bits change from a “0” “1”). AT88SC0808CA [Preliminary] 14 5204AS–CRYPT–6/08 ...

Page 15

... Protocol Selection The AT88SC0808CA supports two different communication protocols. Smartcard Applications: Smartcard applications use ISO 7816-B protocol in asynchronous mode for compatibility and interoperability with industry standard smartcard readers. Embedded Applications: A 2-wire serial interface provides fast and efficient connectivity with other logic devices or micro- controllers ...

Page 16

... Gaining access to the configuration memory requires successful presentation of a secure (or transport) code. The initial signature of the secure (transport) code for the AT88SC0808CA device is $22 E8 3F. This is the same as the WRITE 7 password. The user may elect to change the signature of the secure code anytime after successful presentation ...

Page 17

... Ordering Information Ordering Code Package AT88SC0808C-MJ M2 – J Module AT88SC0808C-MP M2 – P Module AT88SC0808C-PU 8P3 AT88SC0808C-SU 8S1 AT88SC0808CA-TU 8A2 AT88SC0808C-WI 7 mil wafer (1) Package Type M2 – J Module M2 – P Module 8P3 8S1 8A2 Note: Formal drawings may be obtained from an Atmel sales office. 18. Packaging Information Ordering Code: MJ ...

Page 18

... SOIC TOP VIEW TOP VIEW e e SIDE VIEW SIDE VIEW Note: These drawings are for general information only. Refer to JEDEC Drawing MS-012, Variation AA for proper dimensions, tolerances, datums, etc. 1150 E. Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 R AT88SC0808CA [Preliminary TITLE 8S1, 8-lead (0.150" Wide Body), Plastic Gull Wing ...

Page 19

... E and eA measured with the leads constrained to be perpendicular to datum. 5. Pointed or rounded lead tips are preferred to ease insertion and b3 maximum dimensions do not include Dambar protrusions. Dambar protrusions shall not exceed 0.010 (0.25 mm). 2325 Orchard Parkway San Jose, CA 95131 R 5204AS–CRYPT–6/08 AT88SC0808CA [Preliminary ...

Page 20

... TSSOP AT88SC0808CA [Preliminary] 20 5204AS–CRYPT–6/08 ...

Page 21

... Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDI- TIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT ...

Related keywords