IDT82V3280DQ IDT, Integrated Device Technology Inc, IDT82V3280DQ Datasheet - Page 45

no-image

IDT82V3280DQ

Manufacturer Part Number
IDT82V3280DQ
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82V3280DQ

Function
Wan PLL
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Package Type
TQFP EP
Pin Count
100
Mounting
Surface Mount
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V3280DQ
Manufacturer:
SIL
Quantity:
6 224
Table 30: Related Bit / Register in Chapter 3.15
3.15
interrupt status bit. If the corresponding interrupt enable bit is set, any of
the interrupts can be reported by the INT_REQ pin. The output charac-
teristics on the INT_REQ pin are determined by the HZ_EN bit and the
INT_POL bit.
interrupt status bit. The INT_REQ pin will be inactive only when all the
pending enabled interrupts are cleared.
reported by the TDO pin, as determined by the LOS_FLAG_TO_TDO
bit.
Functional Description
IDT82V3280
The interrupt sources of the device are as follows:
All of the above interrupt events are indicated by the corresponding
Interrupt events are cleared by writing a ‘1’ to the corresponding
In addition, the interrupt of T0 selected input clock fail can be
LOS_FLAG_TO_TDO
• AMI violation
• LOS
• T4 DPLL locking status change
• Input clocks for T0 path validity change
• T0 selected input clock fail
• Input clocks for T4 path change to be no qualified input clock
• T0 DPLL operating mode switch
• External sync alarm
available
INT_POL
HZ_EN
INTERRUPT SUMMARY
Bit
MON_SW_PBO_CNFG
INTERRUPT_CNFG
Register
Address (Hex)
0C
0B
45
3.16
The main features supported by the T0 path are as follows:
The main features supported by the T4 path are as follows:
• Phase lock alarm;
• Forced or Automatic input clock selection/switch;
• 3 primary and 3 secondary, temporary DPLL operating modes,
• Automatic switch between starting, acquisition and locked band-
• Programmable DPLL bandwidths from 0.5 mHz to 560 Hz in 19
• Programmable damping factors: 1.2, 2.5, 5, 10 and 20;
• Fast loss, coarse phase loss, fine phase loss and hard limit
• Output phase and frequency offset limited;
• Automatic Instantaneous, Automatic Slow Averaged, Automatic
• PBO to minimize output phase transients;
• Programmable output phase offset;
• Low jitter multiple clock outputs with programmable polarity;
• Low jitter 2 kHz and 8 kHz frame sync signal outputs with pro-
• Master / Slave application to enable system protection against
• Forced or Automatic input clock selection/switch;
• Locking to T0 DPLL output;
• 3 DPLL operating modes, switched automatically or under exter-
• Programmable DPLL bandwidth: 18 Hz, 35 Hz, 70 Hz and 560
• Programmable damping factor: 1.2, 2.5, 5, 10 and 20;
• Fast loss, coarse phase loss, fine phase loss and hard limit
• Output phase and frequency offset limited;
• Automatic Instantaneous holdover frequency offset;
• Low jitter multiple clock outputs with programmable polarity.
switched automatically or under external control;
widths/damping factors;
steps;
exceeding monitoring;
Fast Averaged or Manual holdover frequency offset acquiring;
grammable pulse width and polarity;
single device failure.
nal control;
Hz;
exceeding monitoring;
T0 AND T4 SUMMARY
March 02, 2009
WAN PLL

Related parts for IDT82V3280DQ