CS5345-CQZR Cirrus Logic Inc, CS5345-CQZR Datasheet - Page 24

IC ADC AUD 105DB 200KHZ 48-LQFP

CS5345-CQZR

Manufacturer Part Number
CS5345-CQZR
Description
IC ADC AUD 105DB 200KHZ 48-LQFP
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5345-CQZR

Package / Case
48-LQFP
Number Of Bits
24
Sampling Rate (per Second)
200k
Data Interface
Serial
Number Of Converters
2
Power Dissipation (max)
485mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-10°C ~ 70°C
Mounting Type
Surface Mount
Conversion Rate
192 KSPs
Resolution
24 bit
Number Of Adc Inputs
6
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 10 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.25 V
Supply Voltage (min)
3.13 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1780 - EVALUATION BOARD FOR CS5345
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5345-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
24
4.2.2
4.2.3
4.3
High-Pass Filter and DC Offset Calibration
When using operational amplifiers in the input circuitry driving the CS5345, a small DC offset may be driven
into the A/D converter. The CS5345 includes a high-pass filter after the decimator to remove any DC offset
which could result in recording a DC level, possibly yielding clicks when switching between devices in a mul-
tichannel system.
The high-pass filter continuously subtracts a measure of the DC offset from the output of the decimation
filter. If the HPFFreeze bit (See
the current value of the DC offset for the each channel is frozen and this DC offset will continue to be sub-
tracted from the conversion result. This feature makes it possible to perform a system DC offset calibration
by:
1. Running the CS5345 with the high-pass filter enabled until the filter settles. See the Digital Filter Char-
2. Disabling the high-pass filter and freezing the stored DC offset.
A system calibration performed in this way will eliminate offsets anywhere in the signal path between the
calibration point and the CS5345.
Master Mode
As a clock master, LRCK and SCLK will operate as outputs. LRCK and SCLK are internally derived from
MCLK with LRCK equal to Fs and SCLK equal to 64 x Fs as shown in
Slave Mode
In Slave Mode, SCLK and LRCK operate as inputs. The Left/Right clock signal must be equal to the sam-
ple rate, Fs, and must be synchronously derived from the supplied master clock, MCLK.
The serial bit clock, SCLK, must be synchronously derived from the master clock, MCLK, and be equal to
128x, 64x, 48x or 32x Fs, depending on the desired speed mode. Refer to
tios.
SCLK/LRCK Ratio
acteristics section for filter settling time.
MCLK
MCLK Freq Bits
“High-Pass Filter Freeze (Bit 1)” on page
Table 3. Slave Mode Serial Bit Clock Ratios
Figure 8. Master Mode Clocking
÷1.5
÷1
÷2
÷3
÷4
32x, 48x, 64x, 128x
Single-Speed
000
001
010
011
100
÷256
÷128
÷64
÷4
÷2
÷1
FM Bits
00
01
10
00
01
10
Double-Speed
32x, 48x, 64x
LRCK
SCLK
32.) is set during normal operation,
Figure
Table 3
8.
for required clock ra-
Quad-Speed
32x, 48x, 64x
CS5345
DS658F2